0
Review ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Food & Water Human Health Effects Nanoplastics Sign in to save

Analysing micro- and nanoplastics with cutting-edge infrared spectroscopy techniques: a critical review

Analytical Methods 2024 44 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 70 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Junhao Xie, Aoife Gowen, Wei Xu, Jun‐Li Xu

Summary

This review evaluates cutting-edge infrared spectroscopy techniques for detecting and analyzing micro- and nanoplastics in environmental and food samples. Better detection methods are crucial for understanding human exposure because they allow scientists to measure smaller particles more accurately, including nanoplastics that are small enough to cross biological barriers and accumulate in human tissues.

Study Type Environmental

The escalating prominence of micro- and nanoplastics (MNPs) as emerging anthropogenic pollutants has sparked widespread scientific and public interest. These minuscule particles pervade the global environment, permeating drinking water and food sources, prompting concerns regarding their environmental impacts and potential risks to human health. In recent years, the field of MNP research has witnessed the development and application of cutting-edge infrared (IR) spectroscopic instruments. This review focuses on the recent application of advanced IR spectroscopic techniques and relevant instrumentation to analyse MNPs. A comprehensive literature search was conducted, encompassing articles published within the past three years. The findings revealed that Fourier transform infrared (FTIR) spectroscopy stands as the most used technique, with focal plane array FTIR (FPA-FTIR) representing the cutting edge in FTIR spectroscopy. The second most popular technique is quantum cascade laser infrared (QCL-IR) spectroscopy, which has facilitated rapid analysis of plastic particles. Following closely is optical photothermal infrared (O-PTIR) spectroscopy, which can furnish submicron spatial resolution. Subsequently, there is atomic force microscopy-based infrared (AFM-IR) spectroscopy, which has made it feasible to analyse MNPs at the nanoscale level. The most advanced IR instruments identified in articles covered in this review were compared. Comparison metrics encompass substrates/filters, data quality, spatial resolution, data acquisition speed, data processing and cost. The limitations of these IR instruments were identified, and recommendations to address these limitations were proposed. The findings of this review offer valuable guidance to MNP researchers in selecting suitable instrumentation for their research experiments, thereby facilitating advancements in research aimed at enhancing our understanding of the environmental and human health risks associated with MNPs.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Detection methods of micro and nanoplastics

This review surveyed current detection methods for micro- and nanoplastics across environmental and food matrices, comparing techniques like FTIR, Raman spectroscopy, and mass spectrometry for identifying these emerging contaminants.

Article Tier 2

High-resolution characterization technology for micro-/nano-plastics

This review provides an overview of advanced technologies for detecting and characterizing micro- and nanoplastics, including Raman spectroscopy, infrared imaging, and mass spectrometry techniques. Researchers evaluated the capabilities and limitations of each method, particularly for identifying the smallest plastic particles that are most challenging to measure. The study emphasizes that improving detection at the nanoscale is essential for accurately assessing the environmental and health risks of plastic pollution.

Article Tier 2

Application of Infrared and Near-Infrared Microspectroscopy to Microplastic Human Exposure Measurements

This review evaluates how infrared and near-infrared microscopy techniques are being used to measure human exposure to microplastics from drinking water, dust, food, and air. Researchers found that while these spectroscopic tools are powerful for identifying plastic types and sizes, significant challenges remain in standardizing methods across different sample types. The study highlights that consistent, reliable exposure measurements are essential for understanding whether microplastic levels in everyday environments pose meaningful health risks.

Article Tier 2

Microplastic Detection and Monitoring in Biological and Environmental Systems: A Mini Review of Techniques and Strategies

This mini review compares the major techniques used to detect and measure microplastics in both environmental and biological samples, including infrared spectroscopy, Raman spectroscopy, and mass spectrometry methods. Researchers evaluated the strengths and limitations of each approach for identifying different types and sizes of microplastic particles. The study provides practical guidance for choosing the right detection method depending on the specific research question and sample type.

Article Tier 2

Current techniques for identifying, quantifying, and characterizing micro and nanoplastics with emphasis on strengths, limitations, and challenges

Researchers reviewed current analytical techniques for identifying, quantifying, and characterizing micro- and nanoplastics across environmental matrices. The review highlights the strengths and limitations of methods including FTIR, Raman spectroscopy, and pyrolysis-GC/MS, and calls for standardization to improve comparability across studies.

Share this paper