0
Article Tier 2 Detection Methods Food & Water Policy & Risk Sign in to save

Development of an accreditation process for analytical methods to measure microplastics in drinking water for regulatory monitoring

Chemosphere 2024 5 citations

AI summary Read the abstract

Researchers developed a laboratory accreditation process for analytical methods measuring microplastics in drinking water, establishing performance criteria, proficiency testing protocols, and quality assurance standards to support regulatory monitoring programs.

Polymers
Study Type Environmental

Development of a laboratory accreditation program to ensure competency of laboratories performing analytical measurements is a key step in adopting new analytical measurement methods for regulatory decision-making. Here, we describe California's three-part accreditation process for spectroscopically measuring microplastics in drinking water, and show how data from a multi-laboratory method comparison study informed development of accreditation programs for the resulting methods, which can inform analogous future work for other analytes. The first part is periodic performance evaluation (PE) samples, in which laboratories are provided blind samples of known composition to quantify within acceptable performance limits. The second is inspection, or audit, assessing whether the laboratory has the proper equipment to conduct the work and whether it is correctly employing proper procedures. The third is implementation of a quality management system providing documentation that protocols demonstrated during inspection are continuously maintained. These fell into three broad categories: instrument maintenance; laboratory cleanliness, especially important for microplastics and one that must be accompanied by a blanks measurement and correction process; and training so samples are being processed by qualified analysts. An intercomparison exercise among 22 laboratories was necessary to determine what parameter permutations were important for PE samples, and expected accuracy from competent laboratories. The recommended PE sample composition was two size categories (20-50um and 500um-1mm), two polymer types, and two morphologies (fibers and non-fibers). Discussions among intercomparison exercise participants were key in determining the factors that most contributed to laboratory variability, and the focus for both on-site inspections and quality management systems.

More Papers Like This

Article Tier 2

Monitoring microplastics in drinking water: An interlaboratory study to inform effective methods for quantifying and characterizing microplastics

AI summary Read the abstract

Researchers conducted an interlaboratory study with 22 labs from six countries to evaluate methods for quantifying microplastics in drinking water, finding significant variability between labs and identifying key areas for method standardization.

Article Tier 2

Developing a Methodology for the Testing of Microplastics in Drinking Water Treatment Plants

AI summary Read the abstract

Researchers developed a standardized methodology for testing microplastic removal efficiency at drinking water treatment plants, including sampling, analysis, and reporting protocols. Having consistent methods is critical for comparing microplastic contamination across different water treatment facilities and establishing regulatory benchmarks.

Article Tier 2

Identifying microplastic contamination in drinking water: analysis and evaluation using spectroscopic methods

AI summary Read the abstract

Researchers developed analytical methods to identify and quantify microplastic contamination in drinking water, evaluating extraction efficiency and detection accuracy across different water types and plastic particle sizes. The study assessed health implications based on measured plastic loads in treated water.

Article Tier 2

Innovative reference materials for method validation in microplastic analysis including interlaboratory comparison exercises

AI summary Read the abstract

Researchers developed innovative reference materials for validating microplastic analysis methods, presenting interlaboratory comparison results that support quality assurance and standardization in the growing field of microplastic detection.

Article Tier 2

Development and Application of Sampling and Extraction Methods for Microplastics in Drinking Water

AI summary Read the abstract

Researchers developed and compared sampling and extraction methods for detecting microplastics specifically in treated drinking water, identifying inadequate sample volumes and lack of method recovery validation as common limitations in published studies. The validated in-line filtration method developed in this study improved accuracy and could serve as a template for standardized drinking water microplastic monitoring.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper