We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Can CT Imaging be Used to Investigate Microplastics in Sediments?
AI summary Read the abstract
Researchers evaluated X-ray computed tomography (CT) as a non-destructive method for detecting microplastics in river sediment cores, testing the technique on layered, randomly spiked, and real environmental samples from the Thames estuary to assess its utility as an in-situ identification tool.
https://doi.org/10.1016/j.marpolbul.2023.115350 Introduction: X-ray Computed Tomography (CT) is a three-dimensional non-destructive imaging technique, which could in theory allow for the non-invasive identification of microplastics in-situ within sediment cores. In this study, the utility of CT was explored as a novel technique for the non-destructive analysis of microplastics in river sediments, forming part of a wider study investigating sources and sinks of microplastics in the river Thames estuary, UK. Methods: The technique was tested in three stages: (1) layered cores (for assessing detectability), (2) randomly spiked cores (simulating environmental samples), and (3) environmental samples (real-world examples). Layered and spiked cores were created using a stock of homogenised intertidal foreshore sediment collected from Purfleet on the Thames estuary. Each of the four cores for both types were spiked with a different plastic polymer to test the influence of plastic type on recoverability. They were also categorised as ‘large’ (~4 mm diameter) or ‘small’ microplastics (~125 μm diameter), to assess the impact of size on recoverability. For the environmental samples, two sediment gravity cores were used which had been extracted from a transect of Barking Creek (a tributary of the Thames) as part of the wider study. Results: When examined in layers within artificial cores, all microplastic types could be observed by CT imagery, with good contrast in X-ray attenuation against background sediments. The size and shape were reliably represented, allowing discrete particles to be classified using existing typology (Fig. 1). Differences in attenuation between polymer types suggested that it may be possible to uniquely identify different plastic polymers. Large microplastics were also detectable within spiked cores, having sufficient difference in attenuation to isolate individual microplastics (Fig. 2). Due to limitations on scan resolution, smaller microplastics could not be detected in spiked cores. Imaging of environmental samples revealed two distinct cores in terms of sediment structure, and a range of particle types were visible in the imagery of both (Fig. 3). It was not yet possible to confidently differentiate microplastic particles from others within these cores. Figure 1: Grayscale CT image slices of layered cores, annotated with image average gray level values for different particle types. Figure 2: False colour 3D reconstruction of polypropylene (left) and PET (right) spiked core scans, when suspected microplastics were isolated by a specified grayscale colour range and digitally coloured according to particle volume. Figure 3: CT image slices of environmental cores UT3C (top) and UT3F (bottom). Core UT3C was extracted from Barking Creek (London, UK) and spanned depths of 0-30 cm, while UT3F was from the adjacent saltmarsh, spanning depths of 30-60 cm. Conclusions: This study shows that microplastics can be detected in sediments using CT. As a highly complementary approach, it has potential to be used alongside established techniques to reveal additional information about the sediment structure. While further work is needed to make it a robust, reproducible screening technique for the direct investigation of microplastics in environmental samples, this is an important early step in the use of CT within the field.
More Papers Like This
X-ray computed tomography: A novel non-invasive approach for the detection of microplastics in sediments?
AI summary Read the abstract
Researchers tested whether X-ray computed tomography (CT scanning) can non-invasively detect microplastics in river sediment cores, finding it works well for particles 4 mm or larger but cannot resolve smaller microplastics below 125 μm due to resolution limits. Importantly, CT scanning also revealed sediment layering and structural features that affect where microplastics accumulate — information that is lost when sediment cores are physically extracted and processed by conventional methods. This non-destructive approach could improve how scientists study microplastic distribution in sediments.
High resolution X-ray microtomography as a tool for observation and classification of individual microplastics
AI summary Read the abstract
Researchers investigated X-ray microtomography (microCT) as a non-destructive tool for characterizing microplastics embedded in sediment, demonstrating that the technique could provide detailed internal and external morphological data to help classify individual particles based on structure and composition.
Enhancing microplastic detection in biological tissue with x-ray computed tomography
AI summary Read the abstract
This study tested X-ray computed tomography (CT scanning) as a way to detect microplastics in biological tissue, exploring whether this non-destructive imaging approach could improve on current methods that require chemically processing samples. A non-destructive technique would allow scientists to study microplastic distribution in tissues without destroying the sample, potentially enabling more detailed and repeatable analyses.
Enhancing microplastic detection in biological tissue with x-ray computed tomography
AI summary Read the abstract
This study tested X-ray computed tomography (CT scanning) as a way to detect microplastics in biological tissue, exploring whether this non-destructive imaging approach could improve on current methods that require chemically processing samples. A non-destructive technique would allow scientists to study microplastic distribution in tissues without destroying the sample, potentially enabling more detailed and repeatable analyses.
Non-invasive detection and localization of microplastic particles in a sandy sediment by complementary neutron and X-ray tomography
AI summary Read the abstract
Researchers used neutron and X-ray tomography — scanning technologies that see inside materials without cutting them open — to non-destructively detect and map microplastic particles inside sandy sediment samples, opening new possibilities for studying how microplastics move and accumulate in natural environments.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.