0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Sign in to save

Enhancing microplastic detection in biological tissue with x-ray computed tomography

Zenodo (CERN European Organization for Nuclear Research) 2026 Score: 40 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Viktória Parobková, Lukáš Maleček, Marek Zemek, Tomáš Zikmund, Jozef Kaiser, Jozef Kaiser

Summary

This study tested X-ray computed tomography (CT scanning) as a way to detect microplastics in biological tissue, exploring whether this non-destructive imaging approach could improve on current methods that require chemically processing samples. A non-destructive technique would allow scientists to study microplastic distribution in tissues without destroying the sample, potentially enabling more detailed and repeatable analyses.

Enhancing microplastic detection in biological tissue with x-ray computed tomography

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Enhancing microplastic detection in biological tissue with x-ray computed tomography

This study tested X-ray computed tomography (CT scanning) as a way to detect microplastics in biological tissue, exploring whether this non-destructive imaging approach could improve on current methods that require chemically processing samples. A non-destructive technique would allow scientists to study microplastic distribution in tissues without destroying the sample, potentially enabling more detailed and repeatable analyses.

Article Tier 2

X-ray computed tomography: A novel non-invasive approach for the detection of microplastics in sediments?

Researchers tested whether X-ray computed tomography (CT scanning) can non-invasively detect microplastics in river sediment cores, finding it works well for particles 4 mm or larger but cannot resolve smaller microplastics below 125 μm due to resolution limits. Importantly, CT scanning also revealed sediment layering and structural features that affect where microplastics accumulate — information that is lost when sediment cores are physically extracted and processed by conventional methods. This non-destructive approach could improve how scientists study microplastic distribution in sediments.

Article Tier 2

Can CT Imaging be Used to Investigate Microplastics in Sediments?

Researchers evaluated X-ray computed tomography (CT) as a non-destructive method for detecting microplastics in river sediment cores, testing the technique on layered, randomly spiked, and real environmental samples from the Thames estuary to assess its utility as an in-situ identification tool.

Article Tier 2

High resolution X-ray microtomography as a tool for observation and classification of individual microplastics

Researchers investigated X-ray microtomography (microCT) as a non-destructive tool for characterizing microplastics embedded in sediment, demonstrating that the technique could provide detailed internal and external morphological data to help classify individual particles based on structure and composition.

Article Tier 2

Advancing microplastic detection in zebrafish with micro computed tomography: A novel approach to revealing microplastic distribution in organisms

Researchers tested a new approach using X-ray micro-computed tomography (microCT) to detect and map microplastics inside zebrafish in three dimensions. The non-destructive imaging technique successfully identified polyethylene particles throughout the gut and revealed how their distribution changed over time. This method offers a promising alternative to traditional destructive techniques for studying how microplastics move through living organisms.

Share this paper