0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Sign in to save

Performance evaluation of a hyphenated laser spectroscopy system with conventional methods for microplastic analysis

Scientific Reports 2024 10 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
M. Vasudeva, Anish Kumar Warrier M. Vasudeva, Anish Kumar Warrier M. Vasudeva, M. Vasudeva, Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier M. Vasudeva, U.K. Adarsh, Anish Kumar Warrier U.K. Adarsh, Anish Kumar Warrier U.K. Adarsh, Anish Kumar Warrier U.K. Adarsh, U.K. Adarsh, U.K. Adarsh, V. K. Unnikrishnan, Anish Kumar Warrier V. K. Unnikrishnan, Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier V. K. Unnikrishnan, Anish Kumar Warrier V. K. Unnikrishnan, Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier M. Vasudeva, Sajan D. George, Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier M. Vasudeva, V. K. Unnikrishnan, Sajan D. George, V. K. Unnikrishnan, V. K. Unnikrishnan, V. K. Unnikrishnan, Anish Kumar Warrier V. K. Unnikrishnan, V. K. Unnikrishnan, V. K. Unnikrishnan, V. K. Unnikrishnan, V. K. Unnikrishnan, Anish Kumar Warrier V. K. Unnikrishnan, Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier Anish Kumar Warrier

Summary

Researchers evaluated a combined laser-induced breakdown spectroscopy and Raman spectroscopy system for microplastic analysis. The study found that this hyphenated approach can simultaneously identify polymer type and detect surface-adsorbed heavy metals on microplastics, offering a more efficient alternative to using multiple separate analytical instruments.

Microplastics are one of the concerning environmental pollutants because of their ubiquity. Their capability to adsorb other environmental pollutants increases the risk even further. Existing identification approaches for microplastic characterization for polymer class and their surface-adsorbed heavy metal detection require the utilization of multiple resources and expertise. The article discusses the applicability of a custom-made hyphenated Laser Induced Breakdown Spectroscopy (LIBS)-Raman spectroscopic system in characterizing microplastics by comparing the analytical performance with conventional methods such as Attenuated Total Reflectance- Fourier Transform Infrared (ATR-FTIR) spectroscopy, confocal Raman spectroscopy, and Scanning Electron Microscopy-Energy Dispersive X-ray Spectroscopy (SEM-EDS). Raman analysis identified polyethylene (PE), polypropylene (PP), and polyethylene terephthalate (PET) plastics, which is confirmed by confocal Raman and FTIR study of the same. LIBS study of microplastics detected heavy metals such as Al, Ni, Co, and Zn, along with Ca and Mg trace elements. The cross-examination with EDS validates these trace elements' presence on the microplastics' surface. The results of the reported LIBS-Raman analysis and its validity evaluated using conventional gold-standard methods show the applicability of the proposed methodology in characterizing microplastics from environmental resources with less or no sample preparation in short time.

Sign in to start a discussion.

Share this paper