0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Policy & Risk Remediation Sign in to save

Microplastic removal and risk assessment framework in a constructed wetland for the treatment of combined sewer overflows

The Science of The Total Environment 2024 19 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Chiara Sarti, Alessandra Cincinelli, Alessandra Cincinelli, R. Bresciani, Anacleto Rizzo, David Chelazzi, Fabio Masi

Summary

Researchers assessed microplastic removal performance in a full-scale constructed wetland treating combined sewer overflows and developed a risk assessment framework for these events. They found that the wetland effectively reduced microplastic concentrations, though removal rates varied across different overflow events. The study provides evidence that constructed wetlands can serve as a practical nature-based solution for mitigating microplastic pollution from urban sewer systems.

Combined sewer overflows (CSOs) release a significant amount of pollutants, including microplastics (MPs), due to the discharge of untreated water into receiving water bodies. Constructed Wetlands (CWs) offer a promising strategy for CSO treatment and have recently attracted attention as a potential solution for MP mitigation. Nevertheless, limited research on MP dynamics within CSO events and MP removal performance in full-scale CW systems poses a barrier to this frontier of application. This research aims to address both these knowledge gaps, representing the first investigation of a multi-stage CSO-CW for MP removal. The study presents one year of seasonal data from the CSO-CW upstream of the WWTP in Carimate (Italy), evaluating the correlation of MP abundance with different water quality/quantity parameters and associated ecological risks. The results show a clear trend in MP abundance, which increases with rainfall intensity. The strong correlation between MP concentration, flow rate, and total suspended solids (TSS) validates the first flush phenomenon hypothesis and its impact on MP release during CSOs. Chemical characterization identifies acrylonitrile-butadiene-styrene (ABS), polyethylene (PE), and polypropylene (PP) as predominant polymers. The first vertical subsurface flow (VF) stage showed removal rates ranging from 40 % to 77 %. However, the unexpected increase in MP concentrations after the second free water surface (FWS) stage suggests the stochasticity of CSO events and the different hydraulic characteristics of the CW units have diverse effects on MP retention. These data confirm filtration as the main retention mechanism for MP within CW systems. The MP ecological risk assessment indicates a high-risk category for most of the water samples, mainly related to the frequent presence of ABS fragments. The results contribute to the current understanding of MPs released by CSOs and provide insights into the performance of different treatment units within a large-scale CSO-CW system, suggesting the requirement for further attention.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Microplastics occurrence and fate in full-scale treatment wetlands

Researchers assessed microplastic occurrence and fate across full-scale treatment wetlands, finding that constructed wetlands effectively remove a significant proportion of MPs from wastewater but that removal efficiency varies with wetland design and MP characteristics.

Article Tier 2

Aerated wetland for the treatment of combined sewer overflow: Long-term monitoring of Merone full-scale system

This two-year evaluation of a full-scale aerated constructed wetland treating combined sewer overflow in Italy showed strong removal of conventional pollutants and also captured over 95% of microplastics during storm events. The system was effective even under highly variable hydraulic loads typical of overflow events. The results demonstrate that nature-based water treatment infrastructure can double as a meaningful microplastic capture system, reducing the amount reaching rivers and coastal waters.

Article Tier 2

Fate and removal of microplastics in unplanted lab-scale vertical flow constructed wetlands

Laboratory-scale unplanted vertical flow constructed wetlands were shown to remove microplastics from wastewater, with removal efficiency influenced by particle size, shape, and flow rate, highlighting constructed wetlands as a nature-based option for microplastic mitigation.

Article Tier 2

The fate of microplastics from municipal wastewater in a surface flow treatment wetland

Researchers investigated microplastic retention in a full-scale surface flow treatment wetland receiving municipal wastewater, measuring microplastic concentrations in inflow, outflow, and atmospheric deposition, and finding significant retention within the wetland. Treatment wetlands represent a potential nature-based solution for reducing microplastic discharge to receiving water bodies.

Article Tier 2

Retention of microplastics by interspersed lagoons in both natural and constructed wetlands

Researchers used laboratory wetland models to test how well constructed wetlands with interspersed lagoons and aquatic vegetation can capture microplastic particles from water. Combining vegetated patches with a lagoon achieved microplastic retention rates of up to 99%, suggesting that nature-based wetland designs could be an effective low-cost strategy for filtering microplastics out of wastewater and rivers before they reach the ocean.

Share this paper