Rapid sample preparation to detect microplastics in baby milk powder
Summary
This study developed a rapid sample preparation method to detect microplastics in baby milk powder, addressing the absence of standardized procedures for food matrices. The method enables faster monitoring of microplastic contamination at a critical point of human dietary exposure, particularly for infants.
Microplastics, ubiquitous as it is, could be released into food during production chain, through packaging and by consumer´s use. To determinate human exposure to microplastics is crucial to monitor microplastics in food matrices. The current absence of standard sample preparation procedures to identify and quantify different microplastics according to number and mass have generate time-consuming protocols and lack of comparability among different analytical methods, laboratories and time scales. Monitoring microplastics in complex matrices as food, and in particular in baby milk powder, requires an accurate approach that need to be validate, to ensure the comparability of results. Bottled drinking water or surface waters, for example, can be measured with mass-based methods (TED-GC/MS or Py-GC/MS) directly after filtration. Baby milk powder, instead is more challenging, due to the proteins and fatty acid that clog the filters and contaminate the measuring devices with heavy carry over. In this study, we characterize the baby milk powder by thermogravimetric analysis (TGA) and we tested different treatments for matrix reduction: water, H2O2, citric acids. In particular, the use of citric acid was tested for protein reduction before filtration. Our hypothesis was that citric acid will induce the precipitation of proteins and amino acids, leading to a strong matrix reduction. In fact, this sample pre‑treatment, allowed us to use a higher intake, necessary for representative quantification. Finally, the milk powder was spiked with reference material tablets containing polyethylene terephthalate (PET). The PET was not degraded by the citric acid and high recovery rate was achieved by TED-GC/MS and Py-GC/MS methods. Considering the simplicity and accessibility of this sample preparation and its robust results, this procedure could be easily proposed as a simple sample preparation approach to monitor microplastics by mass-based methods. Also see: https://micro2024.sciencesconf.org/558944/document
Sign in to start a discussion.
More Papers Like This
Rapid sample preparation to detect microplastics in baby milk powder
Researchers developed a rapid sample preparation protocol for detecting microplastics in baby milk powder, addressing the absence of standardized methods for quantifying plastic particles in infant food products. The method provides a practical approach for monitoring microplastic contamination at a critical dietary exposure point for the most vulnerable age group.
Development and validation of analytical methods to detect small microplastics (10 -100 µm) in infant formula milk powder
Researchers developed and validated analytical methods for detecting small microplastics in milk, addressing the need for standardized food safety monitoring given that milk is a dietary staple consumed across all age groups. Methods were validated for sensitivity, recovery, and reliability to support future regulatory monitoring frameworks.
Development and validation of analytical methods to detect small microplastics (10 -100 µm) in infant formula milk powder
Researchers developed and validated analytical methods to detect small microplastics in milk, addressing the challenge of analyzing particles in a complex food matrix. The validated methods confirmed microplastic presence in dairy products and provide tools for routine food safety monitoring.
Sample Preparation Protocol for the Extraction and Raman analysis of Small Microplastics in Infant Milk Formula
Researchers developed a standardized sample preparation protocol for extracting and characterizing microplastics (1-1000 µm) from infant milk formula using chemical digestion to remove complex organic matrix components while preserving particle integrity for µ-Raman spectroscopy analysis.
Sample Preparation Protocol for the Extraction and Raman analysis of Small Microplastics in Infant Milk Formula
Researchers published a standard operating procedure for extracting microplastics from infant milk formula using optimized chemical digestion steps to remove proteins, fats, and carbohydrates while preserving microplastic integrity for subsequent µ-Raman spectroscopy identification.