0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Gut & Microbiome Remediation Sign in to save

Analytical Challenges and Strategies for Particle-Based Analysis of Airborne Micro(nano)plastics in Size-Fractionated Samples Using Microscopy, SEM/EDX, and Raman Spectroscopy

Analytical Chemistry 2024 7 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 45 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Parisa Akbari Dana, Eftade O. Gaga, Kadir Gedi̇k

Summary

This review covered analytical strategies for characterizing airborne microplastics as particles, addressing sampling challenges, detection methods including spectroscopy, and the importance of particle-level analysis for accurate exposure assessment. It identified key methodological gaps and recommended standardization approaches.

Polymers

Inhalable micro(nano)plastics (MNPs) have emerged as a significant global concern due to their abundance and persistence in the atmosphere. Despite a growing body of literature addressing the analytical requirements of airborne MNPs, the issue of inhalable fractions and analysis of slotted substrates remains unclear. Therefore, the objective of this study is to perform a systematic particle-based analysis and characterization of inhalable microplastics (MPs) collected by a high-volume sampler equipped with a five-stage cascade impactor with a size range of 10 μm to <0.49 μm. The efficacy of collection substrates (Teflon and aluminum) was evaluated, as was the impact of particle transfer from the slotted filters on the analysis area and pretreatment methods including chemical digestion for further analysis. The distribution of MNP particles across different slots of a Teflon filter was investigated using Raman microspectrometry to select an appropriate subsample. The results showed the suitability of Teflon filters without any pretreatment for particles down to a single micrometer. As observed by the SEM/EDX analysis, the airborne particles collected in a filter with a submicrometer range (<0.95 μm) showed a decrease in carbon-rich components compared to those stages with higher cutoff sizes. A minimum of 20 particles were analyzed per 1 cm2 of the slotted filter using Raman spectrometry, which revealed a homogeneous distribution of MPs across different slots and yielded a concentration of 452 ± 134 MP/m3 in the first stage of the cascade sampler. The detected MPs were morphologically classified into two main groups: fragments with a size range of 2.8-24.8 μm and fibers with a size range of 28.6-212 μm. Subsequently, the particles were chemically identified as carbon black (tires) and polypropylene. In conclusion, particle-based analysis of size-segregated airborne MNPs presents certain challenges when attempting to analyze particles as small as a single micrometer due to the fact that the aerodynamic diameter of the particles in question and the corresponding analytical limitations that result from this become particularly problematic, especially for cutoffs smaller than 3 μm.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Novel Single-Particle Analytical Technique for Inhalable Airborne Microplastic Particles by the Combined Use of Fluorescence Microscopy, Raman Microspectrometry, and SEM/EDX

Researchers developed a novel single-particle analytical method combining fluorescence microscopy, Raman microspectrometry, and SEM/EDX to characterize inhalable airborne microplastics smaller than 10 µm in ambient PM10 aerosols, addressing a critical gap in understanding respiratory exposure to plastic particles.

Systematic Review Tier 1

A review of airborne micro- and nano-plastics: Sampling methods, analytical techniques, and exposure risks.

This review of 140 articles on airborne micro- and nanoplastics found that diverse sampling and analytical methods make cross-study comparisons difficult, limiting exposure risk assessment. The authors recommend standardization of methods and highlight that active samplers and FTIR/Raman spectroscopy are the most commonly used approaches for collecting and identifying atmospheric plastic particles.

Article Tier 2

Novel Single-Particle Analytical Technique for Inhalable Airborne Microplastic Particles by the Combined Use of Fluorescence Microscopy, Raman Microspectrometry, and SEM/EDX

Researchers developed a new method combining fluorescence microscopy, Raman spectroscopy, and electron microscopy to analyze individual airborne microplastic particles small enough to inhale. The technique can identify both the polymer type and chemical composition of particles under 10 micrometers found in urban air samples. Better tools for characterizing breathable microplastics are essential for understanding respiratory exposure risks.

Article Tier 2

Sampling strategies and analytical techniques for assessment of airborne micro and nano plastics

This review evaluates sampling strategies and analytical techniques for assessing airborne micro- and nanoplastics in indoor and outdoor environments, highlighting methodological limitations and the lack of standardization that hinder cross-study comparisons.

Article Tier 2

Microplastics in Urban Ambient Air: A Rapid Review of Active Sampling and Analytical Methods for Human Risk Assessment

This review evaluated methods for sampling and analyzing microplastics in outdoor urban air to assess human health risks. Active air sampling combined with advanced techniques like micro-Raman spectroscopy can measure the smallest inhalable particles, which are most relevant to health. The authors found that fibers are the most common airborne microplastic and stress that better standardized methods are needed to understand how much microplastic people actually breathe in.

Share this paper