0
Article Tier 2 Detection Methods Environmental Sources Human Health Effects Nanoplastics Remediation Sign in to save

Determining the hydrodynamic diameters of nanoplastics via short-end capillary zone electrophoresis-Taylor dispersion analysis in tandem

AI summary Read the abstract

Researchers developed a novel capillary zone electrophoresis-Taylor dispersion analysis (CZE-TDA) method to measure hydrodynamic diameters of nanoplastics smaller than 1 μm, enabling size characterization of mixed nanoplastic populations with different surface chemistries.

As plastics persist in the environment, they are broken down into smaller pieces through processes including UV degradation and mechanical forces. Current research focuses on developing analytical methods to characterize plastics <1 μm in diameter, known as nanoplastics, as their size is related to their toxicity. We present a novel short-end capillary zone electrophoresis-Taylor dispersion analysis (CZE-TDA) approach for determining the hydrodynamic diameters and size distributions of mixtures of nanoplastics with different surface chemistries. The CZE-TDA approach first separates particles based on electrophoretic mobility through CZE, reflecting compositional differences. In the subsequent TDA step, the hydrodynamic diameters of particles within the separated zones are determined. These steps are performed in a single analysis, using a conventional benchtop instrument with a single detector. The hydrodynamic diameters obtained by CZE-TDA were validated by Dynamic Light Scattering (DLS) and standalone TDA. Individual nanoplastics with different sizes and surface chemistries were analyzed using CZE-TDA, and the hydrodynamic diameters obtained were within 5% error of DLS. Comparable accuracy was observed for binary mixtures of nanoplastics. Our CZE-TDA approach is a promising technique for characterizing the hydrodynamic diameters of nanoplastics in complex environmental mixtures.

More Papers Like This

Article Tier 2

Physicochemical characterization and quantification of nanoplastics: applicability, limitations and complementarity of batch and fractionation methods

AI summary Read the abstract

Researchers evaluated a suite of techniques for measuring the size, shape, and chemical makeup of nanoplastics — plastic particles smaller than 1 micrometer — and found that no single method works for all sample types, especially when particles vary in size or clump together. Combining multiple complementary techniques is essential for reliable nanoplastic characterization, particularly in complex environmental or biological samples.

Article Tier 2

How small a nanoplastic can be? A discussion on the size of this ubiquitous pollutant

AI summary Read the abstract

Researchers explored the question of how small nanoplastic particles can actually be, highlighting the lack of standardized size definitions for this emerging pollutant. They examined the analytical challenges involved in detecting and characterizing nanoplastics at the smallest scales. The study calls for a clearer framework around nanoplastic size boundaries, since particle size is a key factor influencing toxicity and environmental behavior.

Article Tier 2

Convenient Size Analysis of Nanoplastics on a Microelectrode

AI summary Read the abstract

Researchers developed a microelectrode-based method for size analysis of nanoplastics in suspension, enabling convenient, rapid characterization without specialized nanoparticle tracking instruments. The method accurately measured particle size distributions down to the nanometer range and showed potential for integration into routine environmental monitoring workflows.

Article Tier 2

Measuring particle size distribution and mass concentration of nanoplastics and microplastics: addressing some analytical challenges in the sub-micron size range

AI summary Read the abstract

This technical review compared analytical methods for measuring particle size distribution and mass concentration of nano- and microplastics, identifying tunable resistive pulse sensing and centrifugal liquid sedimentation as the most suitable approaches for the 60 nm–5 µm size range.

Article Tier 2

Electrokinetic separation techniques for studying nano- and microplastics

AI summary Read the abstract

Electrokinetic separation techniques including capillary electrophoresis and field-flow fractionation are reviewed for their application to separating, identifying, and quantifying nano- and microplastics, offering advantages over traditional size- and density-based methods that exclude the smallest particles.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper