0
Article Tier 2 Sign in to save

Microplastics and Nanoplastics in Follicular Fluid and in Vitro Fertilisation Outcomes: A Prospective Cohort Study

AI summary Read the abstract

Researchers measured plastic particle levels in ovarian fluid from 203 women undergoing IVF at a Beijing fertility clinic. Higher levels of PVC plastic were linked to fewer eggs retrieved, fewer good-quality embryos, and lower rates of pregnancy and live birth, while two other plastics showed no such link.

Body Systems
Models
Study Type In vitro

OBJECTIVE: To examine the association between follicular-fluid polymer concentrations and in vitro fertilisation (IVF) outcomes. DESIGN: Prospective cohort study. SETTING: An academic fertility centre in Beijing, China. POPULATION: A total of 203 women, of whom 158 were undergoing their first embryo transfer, after excluding seven women who underwent preimplantation genetic testing. METHODS: Polymer concentrations in follicular fluid were measured using pyrolysis-gas chromatography/mass spectrometry. Multivariable linear and logistic regression models were used to assess the associations between polymer concentrations and IVF outcomes. MAIN OUTCOME MEASURES: Live birth was the primary outcome; clinical pregnancy and embryological outcomes were secondary outcomes. RESULTS: Live birth occurred in 62 women (30.54% per included cycle; 39.24% per embryo transfer). For each standard-deviation increase in ln(polyvinyl chloride concentration + 1), adjusted coefficients were -1.328 (95% confidence interval [CI] -2.218 to -0.439) for the number of oocytes retrieved, -0.900 (95% CI -1.541 to -0.258) for the number of two-pronuclear zygotes and -0.599 (95% CI -1.057 to -0.140) for the number of good-quality embryos. The corresponding adjusted odds ratios were 0.547 (95% CI 0.360-0.829) for clinical pregnancy and 0.598 (95% CI 0.403-0.888) for live birth. Neither polystyrene nor polyamide 66 was statistically associated with these outcomes after adjustment. CONCLUSIONS: Higher follicular-fluid polyvinyl chloride concentrations were associated with poorer reproductive outcomes. These observational findings still require confirmation in larger, independent cohorts.

More Papers Like This

Article Tier 2

Polyethylene and Polyvinyl Chloride Nanoplastics in Human Follicular Fluid and Seminal Plasma: Impact on Fertilization and Sperm Quality

AI summary Read the abstract

Researchers detected polyethylene and PVC nanoplastics in both the follicular fluid and seminal plasma of 51 couples undergoing IVF treatment. Higher levels of PVC nanoplastics in seminal plasma were associated with lower sperm concentration and fewer high-quality embryos, while nanoplastics in follicular fluid showed no significant effect on fertilization rates. This is among the first studies to directly measure nanoplastics in human reproductive fluids and link them to reduced fertility outcomes.

Article Tier 2

Associations between concentrations of microplastics in follicular fluid and the risk of diminished ovarian reserve

AI summary Read the abstract

Researchers conducted a case-control study comparing microplastic levels in follicular fluid of patients with diminished ovarian reserve versus controls. Total microplastic abundance was significantly higher in the diminished ovarian reserve group (30.63 vs. 18.48 micrograms per gram), and elevated levels of polyethylene, polypropylene, and PVC were associated with reduced markers of ovarian function.

Article Tier 2

Polyethylene andPolyvinyl Chloride Nanoplastics inHuman Follicular Fluid and Seminal Plasma: Impact on Fertilizationand Sperm Quality

AI summary Read the abstract

Researchers used pyrolysis GC/MS to detect polyethylene (PE) and polyvinyl chloride (PVC) nanoplastics in follicular fluid and seminal plasma from 51 IVF couples. Both polymers were present in both reproductive fluids, and while associations with fertilization outcomes were not statistically significant, the detection of nanoplastics in human reproductive fluids represents a novel concerning finding.

Article Tier 2

Size- and hydrophobicity-dependent accumulation of microplastics in follicular fluid is linked to impaired ovarian reserve in women undergoing medically assisted reproduction

AI summary Read the abstract

Researchers measured microplastic concentrations in follicular fluid and blood from women undergoing fertility treatment and found that nearly all samples contained microplastics. Higher microplastic concentrations in follicular fluid were significantly associated with reduced oocyte yield and lower odds of pregnancy, with evidence suggesting that certain hydrophobic polymers selectively accumulate in the ovary.

Article Tier 2

Polyethylene microplastic exposure adversely affects oocyte quality in human and mouse

AI summary Read the abstract

Researchers found polyethylene microplastics (the most common plastic type) in the fluid surrounding eggs in 86% of women undergoing fertility treatment, and higher levels correlated with lower fertilization rates. Mouse experiments confirmed that polyethylene exposure reduced the number and quality of eggs while increasing inflammation, suggesting microplastics may be a contributing factor to fertility challenges.