Scaling up Microplastic Removal from PET Recycling Wash Water: The Complete Development Path of Organosilane-Induced Agglomeration–Fixation from Feasibility Test to Continuous Operation
AI summary Read the abstract
Researchers tested a chemical treatment method to remove microplastics from wastewater generated at a plastic bottle recycling facility, developing it from small-scale trials into full, ongoing operation. In continuous operation, the method removed about 96.6% of microplastics from the water, performing better than an existing filtering method used at the site.
Post-consumer PET bottle recycling generates wash water highly loaded with microplastics (MPs), predominantly PET. This study traces the development of organosilane-induced agglomeration–fixation from a feasibility test and pilot trials (2021–2024) to continuous operation (since 2025). The treatment required no pH adjustment: it was applied to untreated alkaline wash water (pH up to 10.8) on-site, stored wash water (pH 6.2) in the technical centre, and already neutralised wash water (pH 6.3–6.4) in continuous operation. After parameter optimisation, the pilot plant removed 84.9 ± 1.7% of the MPs on-site (n = 5) and 81.1 ± 4.4% in the technical centre (n = 3), whereas the existing dissolved air flotation removed −42.7% to 68.5%. Subsequently, in continuous operation, monitored by fluorescence-based MP detection, turbidity, and total suspended solids (TSS), the MP removal was 96.6 ± 2.7% (n = 4). A higher stirrer speed reduced it from 98.4–99.1% to 93.1–95.8%, which turbidity and TSS indicated more distinctly. About 1.8 kg of dry solids per m3 were separated. Assuming indirect discharge, the treatment reduces MP emissions to surface water and sewage sludge 6.6-fold with the pilot plant and 24-fold in continuous operation.
More Papers Like This
Upstream Microplastic Removal in Industrial Wastewater: A Pilot Study on Agglomeration-Fixation-Reaction Based Treatment for Water Reuse and Waste Recovery
AI summary Read the abstract
Researchers tested an automated pilot plant using organosilane-induced agglomeration to remove microplastics from industrial packaging-production wastewater at high loads (1,725 mg/L). Across 25 continuous test runs, the system removed 97.4% of microplastics by mass and 99.1% by particle count while also reducing chemical oxygen demand by 78.8%.
Simultaneous Removal of Microplastics and Total Suspended Solids from Wastewater via a Novel Organosilane-Induced Agglomeration–Fixation Method at a Two-Stage Treatment Plant in Greece
AI summary Read the abstract
Scientists tested a new water treatment method in Greece that removes 86% of microplastics from wastewater before it gets released into the ocean. The treatment uses a special chemical process to clump together tiny plastic particles so they can be filtered out more easily. This technology could help reduce the amount of microplastics that end up in our seas and potentially in our food chain.
When Technology Meets Sustainability: Microplastic Removal from Industrial Wastewater, Including Impact Analysis and Life Cycle Assessment
AI summary Read the abstract
Researchers assessed a novel pilot plant that removes microplastics from industrial wastewater using organosilane-based agglomeration followed by belt filtration, and conducted a life cycle assessment. The system achieved 98% MP removal by mass and 99.9987% by particle count while reducing chemical oxygen demand by 96%, with the life cycle assessment confirming the environmental feasibility of the approach.
Effect of embedding a sieving phase into the current plastic recycling process to capture microplastics
AI summary Read the abstract
Introducing a simple dry sieving step between shredding and washing stages in plastic recycling facilities can capture 96–97% of microplastics generated during shredding, compared to the roughly 76% average removal achieved by conventional water-treatment coagulation methods applied after the fact. The study shows that preventing microplastics from entering wash water in the first place is far more effective than trying to remove them from water afterward. This straightforward process modification could significantly reduce the volume of microplastics that plastic recycling plants currently discharge into waterways.
Removal of Microplastics from Waters through Agglomeration-Fixation Using Organosilanes—Effects of Polymer Types, Water Composition and Temperature
AI summary Read the abstract
Organosilane-based agglomeration and fixation was evaluated as a method for removing microplastics from water, with removal efficiency varying by polymer type, water composition, and temperature, demonstrating potential as a scalable treatment approach.