0
Article Tier 2 Sign in to save

Analyses of microplastic release and surface changes in materials used for intraoral devices subjected to sonication-induced aging

AI summary Read the abstract

This planned lab study will test three dental materials, milled acrylic resin, 3D-printed resin, and thermoformed orthodontic aligners, by soaking samples in artificial saliva and aging them with sonication. Researchers will measure microplastic particles released over 14 days and surface roughness changes using microscopy techniques.

Objetivos: Evaluar la liberación de microplásticos (MPs) de distintos materiales poliméricos utilizados en dispositivos intraorales y analizar su relación con la degradación y rugosidad superficial inducidas por un método de envejecimiento acelerado mediante sonicación. Metodología: Se evaluarán tres materiales poliméricos: resina acrílica fresada, resina impresa en 3D y alineador ortodóntico termoformado. Se confeccionarán especímenes estandarizados de cada material, los cuales serán sumergidos en saliva artificial a 37°C y sometidos a un protocolo de envejecimiento acelerado basado en sesiones diarias de sonicación, con recolección del medio a las 24 horas, 7 y 14 días. Se incluirá un grupo control para cada material, mantenido en saliva artificial a 37°C sin sonicación. Los MPs liberados al medio serán analizados mediante Microscopía Electrónica de Barrido (MEB) para determinar tamaño y morfología de las partículas y mediante microscopía de fluorescencia con tinción Nile Red en microscopio holográfico 3D (Nanolive) para corroborar la presencia de micropasticos y analizar su morfologia. Adicionalmente, se evaluará la rugosidad superficial de los especímenes antes y después del envejecimiento. Resultados Esperados: Se espera generar evidencia preliminar sobre la utilidad de este método novedoso de envejecimiento por sonicación, determinando la liberación de MPs desde los materiales evaluados y su relación con los cambios superficiales asociados. Se anticipa identificar diferencias en cantidad, tamaño y morfología de las partículas, así como en la rugosidad superficial entre los distintos materiales tras el protocolo de sonicación.

More Papers Like This

Article Tier 2

Intraoral ageing of aligners and attachments: Adverse effects on clinical efficiency and release of biologically-active compounds

AI summary Read the abstract

This review examines how clear dental aligners and their attachments break down inside the mouth during use, releasing microplastics and chemical compounds from wear and friction. The aging process also reduces the aligners' ability to move teeth as planned. The findings raise questions about the safety of chronic microplastic exposure in the oral cavity from orthodontic appliances.

Article Tier 2

Experimental assessment of damage and microplastic release during cyclic loading of clear aligners

AI summary Read the abstract

Researchers tested three popular brands of clear orthodontic aligners under simulated chewing conditions and found that all released microplastic particles during use. Since patients wear aligners for extended periods each day, this represents a direct and ongoing source of microplastic ingestion, raising questions about the cumulative exposure from dental devices that are growing in popularity.

Article Tier 2

Evaluation of microplastic release from orthodontic clear aligner – A spectroscopic study

AI summary Read the abstract

Researchers evaluated microplastic release from orthodontic clear aligners under simulated oral conditions using Raman microspectroscopy and scanning electron microscopy. The study found that mechanical friction in the mouth can cause these dental devices to shed microplastic particles, raising questions about an overlooked source of direct microplastic exposure for the millions of people who use clear aligners.

Article Tier 2

A spectroscopic study on orthodontic aligners: First evidence of secondary microplastic detachment after seven days of artificial saliva exposure

AI summary Read the abstract

Researchers investigated whether clear orthodontic aligners release microplastics when exposed to artificial saliva over seven days. The study found evidence of microplastic detachment from aligners made by multiple manufacturers, representing the first documentation of secondary microplastic release from these dental devices. The findings raise questions about potential microplastic ingestion by the millions of people who use clear aligners.

Article Tier 2

Microscopic Acid‐Induced Degradation and Elemental Release From Thermoformed and 3D ‐Printed Orthodontic Aligners in a Simulated Gastric Environment

AI summary Read the abstract

Researchers evaluated acid-induced degradation and elemental release from thermoformed and 3D-printed orthodontic aligner materials under simulated gastric conditions, finding that both types released microplastic and nanoplastic particles along with chemical additives under acidic exposure, raising concerns about ingestion risks during orthodontic treatment.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper