0
Article Tier 2 Sign in to save

Quantifying Cellular Nanoplastic Accumulation Using Raman Microscopy

AI summary Read the abstract

Researchers used a laser-based imaging technique to measure how much tiny plastic (nanoplastic) built up inside human intestinal cells grown in a lab dish. The method tracked plastic levels in individual cells at two doses over 24 hours, finding that lower doses sometimes led to more plastic buildup than higher doses, which connected to differences in cell gene activity and survival.

Polymers
Study Type In vitro

Abstract Micro- and nanoplastic contamination poses emerging health risks through ingestion of contaminated food and water, thereby placing the intestinal barrier as the primary interface for nanoparticle translocation following ingestion. In this context, Caco-2 epithelial cells provide a well-established in vitro model of the small intestine barrier, yet label-free quantification of nanoparticle uptake at the single-cell level remains a significant methodological challenge in nanotoxicology. Here, we report a confocal micro-Raman spectroscopy strategy for per-cell quantification of polystyrene nanoparticle (150 nm diameter) accumulation in Caco-2 intestinal epithelial cells. Our approach combines ratiometric analysis, referencing the polystyrene marker band at ∼1002 cm–1 to the cellular amide I band at ∼1660 cm–1, with control-derived thresholding to distinguish cell-associated nanoparticles from endogenous phenylalanine background, followed by single-cell masking to compute quantitative uptake descriptors. Application to cells exposed to 16 and 25 μg/mL polystyrene for up to 24 h revealed concentration-dependent uptake dynamics. Whereas qualitative spatial occupancy suggests greater nanoplastic accumulation at the lower dose, a rigorous quantification─difficult to achieve with conventional fluorescence-based approaches─uncovers the true dynamics at both concentrations, reconciling apparently paradoxical trends with the complementary transcriptional response and cell viability assays presented herein. These findings demonstrate that the ratiometric Raman mapping framework proposed here provides a chemically specific and robust approach for studying nanoparticle–cell interactions relevant to nanoplastic risk assessment, suggesting that spatial organization of cell-associated nanoparticles as well as relative uptake burden may act as critical determinants of cellular bioactivity.

More Papers Like This

Article Tier 2

Raman-spektroskopische Charakterisierung von Zellen und Gewebe nach Exposition mit Nanoplastik

AI summary Read the abstract

Researchers exposed human monocytic THP-1 cells, trophoblasts, and placenta cells to primary and secondary nanoplastic particles at 100 particles/cell in sizes of 200 nm and 60 nm, then used confocal laser scanning microscopy and Raman microspectroscopy to locate and characterize intracellular nanoplastics.

Article Tier 2

Label-free stimulated Raman scattering imaging of intracellular microplastics in mammalian cells

AI summary Read the abstract

Researchers used label-free stimulated Raman scattering imaging to visualize microplastic uptake and distribution inside mammalian cells without fluorescent labels, finding that intracellular microplastics were associated with elevated reactive oxygen species, reduced cell viability, and altered lipid metabolism.

Article Tier 2

Confocal Surface-Enhanced Raman Imaging of the Intestinal Barrier Crossing Behavior of Model Nanoplastics in Daphnia Magna

AI summary Read the abstract

Using advanced Raman imaging, researchers directly observed nanoplastic particles crossing the intestinal wall of water fleas (Daphnia magna) for the first time. They identified two specific cellular mechanisms — clathrin-dependent endocytosis and macropinocytosis — that cells use to absorb the tiny plastic particles. This study provides concrete evidence of how nanoplastics can pass through the gut barrier into the body, a process relevant to understanding human exposure through food and water.

Article Tier 2

Raman Microspectroscopy to Trace the Incorporation of Deuterium from Labeled (Micro)Plastics into Microbial Cells.

AI summary Read the abstract

Researchers applied stable isotope resonance Raman microspectroscopy at the single-cell level to trace the incorporation of deuterium from labeled (micro)plastics into microbial cells, demonstrating a novel method for tracking microbial degradation of plastics at the cellular level.

Article Tier 2

Imaging and quantifying the biological uptake and distribution of nanoplastics using a dual-functional model material

AI summary Read the abstract

Researchers developed a dual-functional nanoplastic model material that allows both imaging and precise quantification of nanoplastic uptake in biological systems. Using surface-enhanced Raman spectroscopy and inductively coupled plasma mass spectrometry, they could track where nanoplastics accumulated in organisms at high resolution. The tool addresses a major gap in nanoplastic research by enabling more accurate measurement of how these tiny particles interact with living tissues.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper