We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Trace PFOA synergistically intensifies nanoplastic-humic acid fouling in forward osmosis: Mitigation using a MXene-TiO2 substrate and a TA/Fe3+ interlayer
AI summary Read the abstract
Lab tests on a water-filtering membrane found that tiny plastic particles and natural organic matter caused fouling (clogging), which got worse when a trace chemical called PFOA was also present. A redesigned membrane with new coatings reduced this clogging and allowed more water to pass through during testing.
Multicomponent fouling arising from the coexistence of per- and polyfluoroalkyl substances (PFAS), nanoplastics (NPs), and natural organic matter (NOM) remains poorly understood and limits membrane-based water treatment. Here, these interactions and their mitigation are examined through coordinated substrate-interlayer engineering in forward osmosis membranes. A hydrogen-bonded MXene-TiO 2 (HMT) composite is incorporated into the polysulfone substrate to improve pore structure, hydrophilicity, and mass transfer, while a tannic acid/Fe 3+ interlayer regulates interfacial polymerization and surface chemistry. Control membranes are employed to decouple the individual and combined effects of these modifications. Fouling experiments under single, binary, and ternary conditions reveal that trace PFAS cause limited fouling independently whereas NPs and NOM produce stronger fouling individually and in combination, while PFOA synergistically intensifies this co-fouling when all three coexist. The modified membrane mitigates this behavior through enhanced hydration, reduced roughness, and a negative surface charge, resulting in lower foulant deposition under ternary conditions. As a result, the water flux of the optimized membrane increased from 5.7 to 11.3 L m -2 h -1 , the reverse salt flux decreased from 5.9 to 4.4 g m -2 h -1 , and the membrane exhibited lower flux decline during the 48-h ternary fouling test and ≥ 94% flux recovery during chemical-cleaning tests. Transport analysis ( A , B , and S ) confirms improved intrinsic selectivity and reduced internal concentration polarization, while microscopic observations verify reduced foulant deposition. These findings clarify how trace PFOA synergistically intensifies multicomponent co-fouling and offer a rational design strategy for next-generation membranes operating in complex water matrices.
More Papers Like This
Synergistic effects of microplastics and organic foulants on the performance of forward osmosis membranes
AI summary Read the abstract
Researchers found that microplastics and humic acid together cause greater fouling of forward osmosis membranes than either contaminant alone, with combined exposure producing a higher flux decline — a key consideration for designing wastewater treatment systems that use membrane filtration.
Nanoplastics-mediated interfacial processes controlling perfluorooctanoic acid transport in forward osmosis
AI summary Read the abstract
Researchers examined how polystyrene nanoplastics with different surface chemistries affect PFAS removal in a forward osmosis membrane system, finding that nanoplastic fouling promotes accumulation of PFOA near the membrane surface — especially for positively charged particles — worsening concentration polarization and complicating PFAS removal from contaminated waters.
Microplastics-resistant FO membranes: Zwitterionic MOF nanoparticles for superior fouling control
AI summary Read the abstract
Researchers developed a new type of forward osmosis membrane modified with zwitterionic metal-organic framework nanoparticles to resist fouling by microplastics. The modified membranes showed a 73 percent improvement in water-attracting properties and only a 17 percent decline in water flow during fouling tests, compared to 60 percent for unmodified membranes. The technology could improve the efficiency of water treatment systems that need to handle microplastic-contaminated water.
Defect-engineered metal organic framework thin film nanocomposite membranes for enhanced forward osmosis performance and microplastic antifouling
AI summary Read the abstract
Researchers engineered a new type of water filtration membrane by embedding specially designed metal-organic framework (MOF) particles into a thin film, achieving a three-fold increase in water flow rate while also becoming significantly more resistant to fouling by microplastics compared to standard membranes. The MOF particles were given controlled structural defects that created additional water transport pathways and made the membrane surface more water-attracting, reducing plastic particle adhesion. More efficient, fouling-resistant membranes could improve the viability of advanced water treatment systems for removing microplastics.
Effects of co-existence of organic matter and microplastics on the rejection of PFCs by forward osmosis membrane
AI summary Read the abstract
This study examined how the presence of both organic matter and microplastics affects the removal of perfluorinated chemicals (PFCs) through forward osmosis membranes used in water treatment. The results showed complex interactions between these contaminants that reduced treatment effectiveness, highlighting challenges in removing multiple co-occurring pollutants from water.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.