0
Article Tier 2 Sign in to save

Performance of the front-end trigger detector for the High-energy Proton Beam Experimental Station (HPES) at CSNS-II

Abstract This study presents a front-end trigger detector for the High-energy Proton Beam Experimental Station (HPES) at the second phase of the China Spallation Neutron Source (CSNS-II). The detector adopts a compact architecture based on plastic scintillator fiber arrays coupled to photomultiplier tubes. Its timing performance was thoroughly evaluated through a series of rigorous tests using picosecond lasers, radioactive sources, cosmic ray muons, muon beams, and pion beams. Experimental results show that the system achieves an intrinsic time resolution of 210 ± 2 ps and maintains a resolution below 900 ps under realistic particle environments and high-flux beam conditions. This work provides substantial experimental support for the detector's performance, and the detector meets the HPES requirement of < 1 ns time resolution.

More Papers Like This

Article Tier 2

Temperature dependence of the time resolution in a SiPM-readout plastic scintillator for cosmic-ray applications

AI summary Read the abstract

This study isn't about human health or microplastics—it's actually physics research testing detectors used to study cosmic rays (high-energy particles from space) aboard balloons and spacecraft. Researchers found that a specific type of particle detector kept working accurately even when temperatures swung from -20°C to 20°C, which matters for scientists because it means these instruments can reliably measure fast-moving particles even in the extreme temperature changes experienced during flight. While this doesn't directly relate to consumer health, it helps advance our understanding of space radiation, which is relevant to astronaut safety and spacecraft design.

Article Tier 2

Characterization of GaN:Si and ZnO:Ga for position-resolved fast timing applications

AI summary Read the abstract

Scientists tested two crystal materials (GaN:Si and ZnO:Ga) as faster, more precise sensors for detecting radiation, finding they respond to particles over 3 times quicker than the current standard material used in imaging systems. This matters because these sensors are used in techniques like detecting explosives or contraband and could improve certain medical and security imaging tools that rely on precisely tracking radioactive particles, potentially making scans more accurate.

Article Tier 2

Characterization of GaN:Si and ZnO:Ga for position-resolved fast timing applications

AI summary Read the abstract

Scientists tested two new light-detecting crystal materials (GaN:Si and ZnO:Ga) that could improve imaging technologies used in medical scanning and security screening, finding they respond over 3 times faster than the current standard material. This matters because faster, more precise detectors could lead to better medical imaging tools—like those used to spot tumors or guide treatments—with sharper detail and potentially lower radiation doses for patients.

Article Tier 2

Performance of the fiber tracker of the Zirè detector onboard NUSES satellite

AI summary Read the abstract

This paper isn't actually about human health or microplastics—it's about space technology. Researchers are building and testing a new type of particle detector for a satellite (NUSES) that will study cosmic radiation, using plastic fibers and tiny light sensors instead of traditional silicon-based detectors. This matters for space science because it could lead to lighter, more efficient tools for studying radiation in space, which indirectly helps us understand risks to astronauts and equipment from cosmic rays—but it has no direct connection to microplastics or everyday consumer health.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper