Monitoring microplastics in wastewater treatment plants by exploiting the innovative Laser Direct InfraRed (LDIR) chemical imaging technique
AI summary Read the abstract
Scientists tested a new laser imaging tool to count tiny plastic particles in wastewater, and found that treatment plants remove about 91% of microplastics before releasing water back into the environment. Still, the smallest plastic bits and fibers were the hardest to filter out, meaning some inevitably slip through into rivers and, potentially, our water supply.
Monitoring microplastics in wastewater treatment plants by exploiting the innovative Laser Direct InfraRed (LDIR) chemical imaging technique Abstract MPs (i.e. plastic particles in the size range 1 µm – 5 mm of primary or secondary origin [1]) became a contaminant of increasing concern [2]. The role of wastewater treatment plants (WWTPs) as potential sources of microplastic pollution in aquatic ecosystems was pointed out in the literature [3,4]. To date, the lack of reference methodologies represents a bottleneck for MPs monitoring purposes, thus highlighting the need for effective detection, quantification, and characterization methods also in view of a regulatory framework development. In this perspective, this work aims to propose a robust method for monitoring MPs in WWTPs through the innovative Laser Direct InfraRed (LDIR) chemical imaging technique. Since the LDIR technique is still poor investigated for its potential in detecting MPs in wastewaters, this work firstly aimed at fine-tuning both experimental and analytical procedures. Various pre-treatment methods were preliminary compared, leading to the following optimized protocol: (i) sample concentration by vacuum-filtration and subsequent recovery of the material retained on the filter via backwashing with ultrapure water; (ii) chemical digestion via Fenton reaction to remove organics [5]; (iii) density separation in 30 % (w/w) ZnCl2 aqueous solution to remove inorganics (optional); (iv) MPs recovery by vacuum-filtration and backwashing of the filter with ethanol. The dispersions of MPs in ethanol thus obtained were analysed by Agilent 8700 LDIR. Chemical identification of MPs was carried out via real-time matching of the acquired IR spectra with the integrated libraries. Particles recognized as 'cellulosic' were included in the MPs counting since LDIR workflow associates to this polymeric class both cellulose of natural origin and chemically modified/semi-synthetic cellulose (e.g. artificial textile fibers). Size and morphology characterization of the detected particles was performed based on the dimensional and geometric parameters given by the LDIR analysis (i.e. width, height, equivalent diameter, aspect ratio, circularity, etc.): MPs were hence classified into fibers, spheres, pellets and fragments, and a characteristic dimension was assigned to each of them (Table 1). A large WWTP located in Tuscany (Italy) treating both municipal and industrial wastewaters (the latter partially collected to the plant by a separate sewer system) was selected as case-study to apply the above-described methodology. 24-hour composite samples were collected by autosamplers (200 mL sampled each 30 minutes) in the following sections: influent from separate industrial sewer (INSeparate industrial sewer), inlet after union of flows from combined and separate sewers (IN) and effluent (OUT). Preliminary tests were carried out to identify the minimum sample volume to be processed and hence characterized by LDIR as above. Blank control samples were processed to quantify the potential microplastic cross-contamination deriving from both sampling and pre-treatment phases (and hence to subtract it from the MPs concentration in the experimental samples). The results related to the application of the fine-tuned methodologies to the selected case-study are reported below. Preliminary analyses indicated that the MPs concentrations in all treated samples from the monitored WWTP decreased with increasing the processed volume up to a achieve an almost constant value for the 1 L-treated aliquots. For summary constrains, only data related to 1 L-aliquots, judged as sufficiently representative, are hence presented. Considering an average MPs recovery rate of 96% for the applied pre-treatment, the overall concentrations of MPs estimated from the LDIR analysis were about 2.24·105 and 2.03·104 items/L for IN and OUT, respectively (8.08·104 and 4.06·103 items/L for IN and OUT, respectively, without including cellulosic materials in the particle counting). According to these results, it is possible to predict a MPs removal efficiency of about 91% along the water line of the monitored WWTP (that increased up to around 95% if cellulosic particles are not considered), in line with literature data [4]. MPs concentrations (including cellulosic particles) in the range 1.67·105 – 2.26·105 items/L were observed for INSeparate industrial sewer, thus suggesting that a large fraction of MPs entering the WWTP derived from the industrial discharges. The physical and chemical characterization of the detected MPs is summarized in Figure 1. Particles of various origin (mainly in the form of fragments and pellets lower than 200 µm in size and fibers of 100–200 µm) were found in the influent, with a predominance of cellulose-derived materials (64%) followed by polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), polyurethane (PU) and acrylonitrile butadiene styrene (ABS). These findings agreed with literature data: the lowest removal efficiencies are usually reported for the smallest plastic particles (<190 µm) and fibers that, thanks to their morphology, can more easily by-pass various process units in WWTPs [4]. In summary, coherent results were obtained for the monitored WWTP in terms of both estimated removal efficiency and type of plastic particles detected, which were consistent with the nature of treated wastewater. Further methodological insights related to both non-described results and ongoing activities will be presented at the Conference. This paper was presented at WEFTEC 2026 in New Orleans, Louisiana. Presentation time 09:00:00 09:30:00 Session time 8:30:00 9:30:00 Session Microplastic Removal and Insights From New Techniques Session location Ernest N. Morial Convention Center Topic Disinfection and Public Health, Microconstituents and Contaminants of Emerging Concern (Non-PFAS), Research and Innovation Topic Disinfection and Public Health, Microconstituents and Contaminants of Emerging Concern (Non-PFAS), Research and Innovation Author(s) Gori, Riccardo, Pagliaccia, Benedetta, Gentilesca, Pietro, Lubello, Claudio Author(s) R. Gori 1 , B. Pagliaccia 1 , P. Gentilesca 1 , C. Lubello 1 Author affiliation(s) University of Florence, 1 University of Florence, 1 University of Florence, 1 University of Florence, 1 Source Proceedings of the Water Environment Federation Document type Conference Paper Publisher Water Environment Federation Print publication date Sep 2026 DOI 10.2175/193864718825160560 Volume / Issue Content source WEFTEC Copyright 2026 Word count 18 Purchase price $11.50 Get access Log in Purchase content Purchase subscription You may already have access to this content if you have previously purchased this content or have a subscription. Log in Need to create an account? You can purchase access to this content but you might want to consider a subscription for a wide variety of items at a substantial discount! Purchase access to 'Monitoring microplastics in wastewater treatment plants by exploiting the innovative Laser Direct InfraRed (LDIR) chemical imaging technique' Add to cart Purchase a subscription to gain access to 18,000+ Proceeding Papers, 25+ Fact Sheets, 20+ Technical Reports, 50+ magazine articles and select Technical Publications' chapters. Log in to view subscription options Log in to view rental option
More Papers Like This
Methodologic insights aimed to set-up an innovative Laser Direct InfraRed (LDIR)-based method for the detection and characterization of microplastics in wastewaters
AI summary Read the abstract
Researchers developed and validated a method using Laser Direct Infrared imaging technology to detect and characterize microplastics in wastewater. Testing at a large municipal treatment plant in Italy, they found that the facility removed about 82% of microplastics, with most remaining particles smaller than 100 micrometers. The study provides a reproducible analytical approach that could help standardize how microplastic contamination in wastewater is measured and compared across different facilities.
Identification of microplastic in effluents of waste water treatment plants using focal plane array-based micro-Fourier-transform infrared imaging
AI summary Read the abstract
Researchers analyzed effluent from 12 wastewater treatment plants in Germany and found microplastics in all of them, with estimates of up to 4 billion particles discharged per plant annually — predominantly polyethylene fragments and polyester fibers. Notably, one plant with an additional post-filtration step reduced microplastic discharge by 97%, showing that advanced filtration can dramatically cut the flow of plastic particles into waterways.
Identification and Quantification of Microplastics in the Marine Environment Using the Laser Direct Infrared (LDIR) Technique
AI summary Read the abstract
Researchers evaluated the laser direct infrared (LDIR) technique for identifying and quantifying marine microplastics, demonstrating it as a faster and more automated alternative to conventional FTIR methods with comparable accuracy.
Identification and assessment of microplastics in wastewater treatment plants using laser direct infrared spectroscopy and depolymerization-coupled liquid chromatography–tandem mass spectrometry
AI summary Read the abstract
Researchers combined laser direct infrared spectroscopy and depolymerization-coupled LC-MS/MS to comprehensively characterize microplastics in wastewater treatment plants, finding complementary information from each method and documenting MP types and distribution across treatment stages.
Quantification of microplastic mass and removal rates at wastewater treatment plants applying Focal Plane Array (FPA)-based Fourier Transform Infrared (FT-IR) imaging
AI summary Read the abstract
This study quantified microplastic mass and calculated removal rates at wastewater treatment plants, finding that while plants remove a large proportion of incoming microplastics, the residual discharge still represents a substantial ongoing input to receiving water bodies.