0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Nanoplastics Remediation Sign in to save

Development of hydroxyapatite-enhanced membrane for nanoplastics removal: Multiple scenarios and mechanism exploration

Journal of Hazardous Materials 2025 Score: 38 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Mengna Li, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Guohe Huang, Mengna Li, Shuguang Wang, Jing Huang Zeyuan Xu, Guohe Huang, Mengna Li, Mengna Li, Jing Huang

Summary

Researchers developed a novel hydroxyapatite-functionalized PVDF membrane (HAPF) for nanoplastics removal, achieving a water flux of 4376 LMH and high polystyrene nanoplastic rejection efficiency, with the optimized membrane prepared via a one-step method at pH 7.3.

Polymers
Study Type Environmental

Nanoplastics (NPs) are widespread in wastewater systems and more toxic than microplastics (MPs), necessitating effective removal techniques. Although membranes can effectively remove MPs, their efficiency and mechanisms for NPs removal require further study. A novel hydroxyapatite functionalized PVDF (HAPF) membrane was developed for NPs removal. The optimized HAPF membrane was prepared via a one-step method with 800 mg/L HAP at pH 7.3 for 8 hours. It achieved a water flux of 4376.44 LMH, 3.4 times higher than that of the pristine PVDF membrane, while maintaining a polystyrene (PS) NPs rejection above 99.5 %. The HAPF membrane maintained 95 % of its pure water flux when treating wastewater with only PS NPs, but exhibited severe flux decline under varying conditions, such as surface-functionalized PS NPs, pH changes, or coexisting contaminants. Among these, the presence of MgSO alongside PS NPs caused the most severe water flux reduction, with the HAPF membrane undergoing complete blocking, followed by the formation of a cake layer. XDLVO results revealed that there is an attractive interaction between the HAPF membrane and PS NPs, primarily driven by acid-base interaction. The HAPF membrane exhibited significantly lower R and R values than the PVDF membrane and achieved a flux recovery rate of 92.94 % over multiple fouling-cleaning cycles. Its water flux was 18.9 times that of the PVDF membrane during long-term filtration. The developed HAPF membrane holds significant potential for advanced water treatment and fouling resistance .

Sign in to start a discussion.