0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Policy & Risk Sign in to save

Harmonizing infrared spectroscopic techniques for microplastic identification: a comparative evaluation of ATR and µFTIR transmission and reflection modes

2025 Score: 38 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Bárbara Rodrigues Geraldino, Stella Melgaço, Daniele Maia Bila

Summary

Researchers systematically compared the performance of Attenuated Total Reflectance (ATR) and micro-Fourier Transform Infrared Spectroscopy (muFTIR) in both transmission and reflection modes for identifying microplastics from twelve common real-world plastic products, providing guidance on optimizing spectroscopic technique selection.

Abstract This study systematically evaluated the performance of Attenuated Total Reflectance (ATR) and micro-Fourier Transform Infrared Spectroscopy (µFTIR) in transmission and reflection modes for the identification of microplastics (MPs) from real-world plastic products. Twelve common polymers were analyzed in two particle size ranges (500 µm and 100 µm). Identification quality was assessed using the Hit Quality Index (HQI), with a validation threshold of ≥ 70%. ATR analysis of 500 µm particles yielded HQI values > 80% for all polymers, with PET (97.2%), ABS (93.2%), and EVA (92.3%) achieving > 90%, demonstrating high spectral fidelity and reproducibility. µFTIR exhibited significant size-dependent variation: for 100 µm particles, reflection mode (R100) achieved HQI values > 85% for most polymers, including 94.5% for PS and 93.7% for epoxy resin. Conversely, µFTIR performance declined for 500 µm particles, with HQI values < 70% for PET, PS, epoxy resin, and PP. ANOVA (p < 0.0001) and Tukey’s post hoc test confirmed significant differences across techniques and particle sizes, with R100 performing comparably to ATR. These results highlight the influence of particle morphology and acquisition mode on spectral identification and emphasize the need for harmonized analytical protocols. These findings contribute empirical support for the refinement of current standards (e.g., ASTM D8333-20, ISO 24187:2023) recommending HQI ≥ 80% as a reliable threshold for polymer identification via µFTIR.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Detection of Sub-20 μm Microplastic Particles by Attenuated Total Reflection Fourier Transform Infrared Spectroscopy and Comparison with Raman Spectroscopy

Researchers compared two spectroscopy techniques for detecting microplastic particles smaller than 20 micrometers. They found that ATR-FTIR was more sensitive for the smallest particles (6 micrometers), while Raman spectroscopy performed better with larger particles. The study also identified spectral patterns that could serve as indicators of particle size, opening new possibilities for quickly classifying microplastic populations without time-consuming imaging.

Article Tier 2

Optimizing microplastic analysis through comparative FTIR and raman spectroscopy: Addressing challenges in environmental degradation studies

This study optimized microplastic analysis by comparing FTIR and Raman spectroscopy approaches for identifying degraded polymer particles in environmental samples where photooxidation and mechanical fragmentation have altered spectral signatures. A combined spectroscopy approach outperformed either technique alone for accurately identifying degraded microplastics in complex environmental matrices.

Article Tier 2

Analysis of environmental microplastics by vibrational microspectroscopy: FTIR, Raman or both?

This study reviewed analytical methods for environmental microplastic analysis using vibrational microspectroscopy — comparing FTIR, Raman, and related techniques — and provided guidance on method selection for different sample types and research questions.

Article Tier 2

Contributions of Fourier transform infrared spectroscopy in microplastic pollution research: A review

This review covers advances in Fourier transform infrared (FTIR) spectroscopy techniques — including chemical imaging — for identifying polymer types in microplastic samples and tracing their fate in different environmental matrices.

Article Tier 2

Refined Analysis of Microplastics: Integrating Infrared and Raman Spectroscopy

This study optimized the use of Fourier Transform Infrared Spectroscopy (FTIR) and Raman spectroscopy for characterizing microplastics in aquatic environments, finding that integrating both techniques improves identification accuracy and physicochemical characterization.

Share this paper