Toward the future of firefighter gear: Assessing fluorinated and non-fluorinated outer shells following simulated on-the-job exposures
AI summary Read the abstract
This study evaluated traditional PFAS-based and newer non-PFAS water-repellent coatings on firefighter turnout gear after simulated weathering, thermal, and laundering exposures. Both coatings performed similarly for thermal protection and water repellency, but non-PFAS fabrics lacked oil repellency — posing a potential flammability hazard — and both chemistries shed particles during aging, highlighting important safety trade-offs in transitioning away from PFAS.
In 2022, the occupation of firefighting was categorized as a "Group 1" carcinogen, meaning it is known to be carcinogenic to humans. The personal protective equipment that structural firefighters wear is designed to safeguard them from thermal, physical, and chemical hazards while maintaining thermo-physiological comfort. Typically, the outer layer of structural turnout gear is finished with a durable water and oil-repellent (DWR) based on per- and polyfluoroalkyl substances (PFAS) that helps limit exposure to water and hazardous liquids. The PFAS-based aqueous emulsion typically used in DWR finishes is highly persistent and can cause various health problems if absorbed into the body through ingestion, inhalation, and/or dermal absorption. In response, the U.S. Fire Service has begun using non-PFAS water repellants in firefighter turnout gear. This study aims to evaluate the performance of both traditional PFAS-based and alternative non-PFAS outer shell materials. The study involved exposing both PFAS-based and non-PFAS DWR outer shell materials in turnout composites to simulated job exposures (i.e., weathering, thermal exposure, and laundering) that artificially aged the materials. After exposures, samples were evaluated for repellency, durability, thermal protection, and surface chemistry analysis to determine any potential performance trade-offs that may exist. Non-PFAS outer shell fabrics were found not to be diesel/oil-repellent, posing a potential flammability hazard if exposed to diesel and subsequent flame on an emergency response. Both PFAS-based and non-PFAS sets of fabrics performed similarly in terms of thermal protective performance, tearing strength, and water repellency. The surface analysis suggests that both PFAS and non-PFAS chemistries can degrade and shed from fabrics during the aging process. The study indicates that firefighters should be educated and trained regarding the potential performance trade-offs, such as oil absorption and flammability concerns when transitioning to non-PFAS outer shell materials.
More Papers Like This
Profiles of per- and polyfluoroalkyl substances in firefighter turnout gear and their impact on exposure assessment
AI summary Read the abstract
Researchers analyzed PFAS profiles in firefighter turnout gear before and after wear-and-tear cycles, finding that mechanical stress and laundering release polymeric and short-chain PFAS from textile treatments, increasing dermal and inhalation exposure risks for firefighters during active use.
Analysis of per- and polyfluoroalkyl substances (PFAS) extraction from contaminated firefighting materials: Effects of cleaning agent, temperature, and chain-length dependencies
AI summary Read the abstract
Researchers tested how effectively 22 types of PFAS "forever chemicals" — used in firefighting foam and gear — can be removed from contaminated materials using different washing methods and temperatures. They found that shorter-chain PFAS compounds wash out more easily, and that higher temperatures improve removal, but PFAS levels can slowly rebound in materials days after cleaning.
Firefighters’ exposure to per-and polyfluoroalkyl substances (PFAS) as an occupational hazard: A review
AI summary Read the abstract
This review examines how firefighters face elevated cancer risk from occupational exposure to PFAS, a class of toxic "forever chemicals" found in their protective gear, firefighting foam, and fire station dust. While focused on PFAS rather than microplastics directly, the research is relevant because both PFAS and microplastics are persistent environmental pollutants that accumulate in the body. PFAS are also commonly found attached to microplastic surfaces, making microplastics a potential carrier of these carcinogenic chemicals.
An Outdoor Aging Study to Investigate the Release of Per- And Polyfluoroalkyl Substances (PFAS) from Functional Textiles
AI summary Read the abstract
Researchers investigated the release of per- and polyfluoroalkyl substances from functional textiles during outdoor weathering in Sydney, finding that PFAS-treated polyamide fabrics release fluorinated compounds into the environment through aging and degradation.
Research on the PFAS release and migration behavior of multi-layer outdoor jacket fabrics
AI summary Read the abstract
Researchers tracked PFAS release from DWR-treated outdoor jacket fabrics through aging, abrasion, and washing, finding that prolonged use concentrates perfluoroalkyl acids in inner fabric layers and significantly elevates fluorine and microfiber shedding into wash effluents — levels exceeding current regulatory limits and suggesting current chemical-by-chemical PFAS regulations are inadequate.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.