0
Article Sign in to save

Towards the Development of an In-Process Quality Monitoring System for Polyethylene Recyclates by Pyrolysis Gas Chromatography Ion Mobility Spectrometry

AI summary Read the abstract

Researchers tested a compact pyrolysis–gas chromatography–ion mobility spectrometry (Py-GC-IMS) system for detecting PET contamination in polyethylene recyclates as part of in-process quality monitoring. The system successfully identified PET-specific chemical fingerprints against a polyethylene background, demonstrating its potential as a sensitive, low-cost tool for ensuring recyclate purity.

Polymers

Abstract Over the past few decades, the topic of recycling has become increasingly prominent in the field of sustainable materials and circular economy. One significant challenge is the physical separation of different types of plastics to obtain recyclates of one plastic type as pure as possible with comparable quality and properties to those of virgin material. Given the substantial effort involved in such separation, small amounts of contamination from other plastics may be tolerated. However, these contaminations must be monitored to ensure high-level recyclate quality. In recent years, compact, low-cost ion mobility spectrometers (IMS) with high analytical performance have been developed, and have thus become widely used in a variety of sensing applications. Due to their high sensitivity, IMS are particularly suited for detecting lowest concentration levels of various compounds, as required for the detection of impurities in recyclate quality monitoring. When coupled to a miniature gas chromatograph (GC), GC-IMS reach even higher separation power while being still compact. To bring recyclate samples to the gas phase, pyrolysis (Py) is used in this work. A first feasibility study was conducted to assess the potential of such a pyrolysis–gas chromatography-ion mobility spectrometer (Py-GC-IMS) with the objective of detecting contaminations of polyethylene terephthalate (PET) in polyethylene (PE) recyclates. The study clearly demonstrates the ability to identify PET-related fingerprints while suppressing the PE background matrix by design so that Py-GC-IMS seems a promising approach for in-process monitoring PET contaminations in PE recyclates.

More Papers Like This

Article

Application of analytical pyrolysis for the detection of plastics and microplastics in the environment

AI summary Read the abstract

This master's thesis evaluated pyrolysis-gas chromatography-mass spectrometry (Pyr-GC-MS) as a sensitive and accurate method for detecting microplastics and nanoplastics in environmental samples at very low concentrations. The study demonstrated that Pyr-GC-MS can distinguish polymer types in complex real-world samples, positioning it as a promising tool for microplastic analysis.

Article Tier 2

Analysis of polyethylene microplastics in environmental samples, using a thermal decomposition method

AI summary Read the abstract

Researchers developed a thermal analysis method using pyrolysis-GC/MS to identify and quantify polyethylene microplastics in environmental samples without relying on visual sorting or density separation. The approach provides a more objective and automatable way to measure microplastic mass in complex environmental matrices.

Article Tier 2

Size-resolved identification and quantification of micro/nano-plastics in indoor air using pyrolysis gas chromatography-ion mobility mass spectrometry

AI summary Read the abstract

A novel pyrolysis gas chromatographic cyclic ion mobility mass spectrometer method was developed to identify and quantify micro- and nanoplastics smaller than 1 micrometer in indoor air, finding four common plastic types in tested samples.

Article Tier 2

Secondary reactions in the analysis of microplastics by analytical pyrolysis

AI summary Read the abstract

Polymer interactions during analytical pyrolysis of mixed microplastic samples were investigated, finding that co-pyrolysis of PET with PVC and polyamides produces secondary reaction products not characteristic of any individual polymer, which could compromise the accuracy of pyrolysis-GC-MS identification in real environmental samples.

Article Tier 2

Microplastics Identification by Pyrolysis Gas Chromatography Mass Spectrometry (py-GCMS)

AI summary Read the abstract

This paper reviews pyrolysis gas chromatography mass spectrometry (Py-GC/MS) as a method for identifying and quantifying microplastics in environmental samples. The technique can identify specific polymer types even in complex environmental matrices where visual identification is difficult.