We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Microplastic detection in saline water utilizing a microfluidic sensor with MXene-coated electrodes and a Wheatstone bridge
Summary
Engineers developed a microfluidic sensor with MXene-coated electrodes and a Wheatstone bridge circuit for detecting microplastics in salty water, overcoming a key challenge that limits most electrical sensors. The device successfully detected polystyrene microplastics ranging from 1 to 10 micrometers in saline conditions using simple direct current. This advancement could enable practical in-situ monitoring of microplastic contamination in marine and coastal environments.
In situ detection of microplastics in aquatic environments remains challenging, with factors such as variable salinity significantly impacting sensor performance-particularly for systems that rely on electrical signal transduction. Here, we present an electro-microfluidic sensor incorporating a Wheatstone bridge and MXene-coated microwires for enhanced in situ detection of microplastics in salty water. The sensor significantly improves upon state-of-the-art technology by addressing key challenges, including reduced sensitivity and detection limits in saline water, clogging, reliance on sophisticated fabrication methods, and the need for baseline blank solutions. Using a simple DC current, the sensor effectively detects polystyrene microplastics (1-10 µm) within a concentration range 1-25 ppm, in the presence of 0-1000 ppm NaCl, representative of freshwater salinity. As a DC current is applied between two MXene-coated microwire electrodes in a microchannel, an electrophoretic force is generated, concentrating microplastics at the anode electrode. This leads to a reduction in electrical resistance, which enables the quantification of microplastics using the sensor as one of the arms of a Wheatstone bridge. Without the Wheatstone bridge and microwire MXene coating, the sensor's sensitivity significantly diminished at salinity levels above 650 ppm NaCl, especially for larger microplastics (10 µm). Bridge balancing suppressed baseline drift and raised the signal-to-noise ratio, retaining full sensitivity at 1000 ppm NaCl. The optimized sensor demonstrated a power-law response at 650 ppm NaCl and achieved limits of detection and quantification of 0.825 and 3.38 ppm, respectively. This work lays the foundation for low-cost, portable, and sensitive microplastic detection in saline aquatic samples, paving the way towards developing real-time, in situ sensors for environmental monitoring.
Sign in to start a discussion.
More Papers Like This
Microfluidic Sensor for Microplastic Detection in Saline Freshwater: Enhancements by Wheatstone Bridge and MXene-Coated Electrodes
Researchers developed a microfluidic sensor combining a Wheatstone bridge circuit and MXene-coated microwire electrodes to detect microplastics in saline freshwater, achieving a three-fold improvement in sensor response compared to unenhanced designs. The Wheatstone bridge improved signal stability by detecting minute resistance changes while MXene coatings enhanced particle capture efficiency, addressing the critical problem of reduced sensor performance in high ionic-strength environments.
Electrochemical Detection of Microplastics in Water Using Ultramicroelectrodes
Researchers developed a new electrochemical method for detecting microplastics in water using ultramicroelectrodes. The technique works by monitoring changes in electrical current when microplastic particles collide with and adsorb onto the electrode surface, and the size distributions obtained closely matched independent measurements, demonstrating its potential as a practical detection tool.
Microplastic in situ detection based on a portable triboelectric microfluidic sensor
Researchers developed a portable triboelectric microfluidic sensor that detects microplastics in water by measuring electrical charges generated as particles flow through a microchannel, demonstrating linear response to polystyrene particle size and concentration for field-deployable environmental monitoring.
Detection of microplastics by microfluidic microwave sensing: An exploratory study
Researchers developed a compact microwave sensor on a microfluidic chip to detect microplastics in water samples. The system works by measuring how the presence of plastic particles changes the electrical properties of water. While the technology shows promise as a rapid and portable detection method, its current sensitivity needs improvement before it can detect the low microplastic concentrations typically found in natural freshwater.
A microfluidic approach for label-free identification of small-sized microplastics in seawater
Researchers developed a microfluidic approach for label-free identification of small microplastics in seawater, using impedance-based detection to distinguish different polymer types without chemical labeling, enabling faster and more practical environmental monitoring.