0
Article Tier 2 Detection Methods Environmental Sources Policy & Risk Remediation Sign in to save

Effects of pre-treatment on characterization of microplastics in biosolids via optical photothermal infrared spectroscopy

Journal of Hazardous Materials 2025 3 citations

AI summary Read the abstract

Researchers compared three sample preparation protocols for characterizing microplastics in biosolids using optical photothermal infrared (O-PTIR) spectroscopy. Fenton oxidation combined with cellulase treatment gave the best results, and O-PTIR outperformed conventional Raman and FTIR for identifying particles in complex organic matrices.

Microplastics (MPs) in biosolids used as soil amendments are of growing concern. The purpose of this study was to improve the characterization of MPs in complex biosolid matrices by optimizing sample preparation for morphological and chemical analyses with different spectroscopic techniques. We compared extraction procedures involving Fenton oxidation (F), Fenton plus sodium dodecyl sulfate (SDS), and Fenton plus cellulase (FE). We performed partial particle sample counting along with a helical shape, corresponding to 56 % of sample area, and total particle counting. Chemical characterization was performed using sub-micron optical-photothermal infrared (O-PTIR) spectroscopy, and the results were compared with those obtained via commonly employed Raman and Fourier transform infrared absorption microspectroscopy technique (µ-FTIR). Our FE protocol yielded a slightly higher total sample mass removal (97 %±0.3 %) compared to other pre-treatment methods. No significant difference was observed in the total MPs count between the two approaches, indicating a homogeneous distribution across the filter and supporting reliable quantification using only half the filter in the helical method. O-PTIR's high spatial resolution (down to 0.5 µm) and absence of spectral artefacts compared to Raman and µ-FTIR enabled accurate identification of fine fibers (2 µm wide) and small particles (∼5 µm). Single-frequency O-PTIR imaging revealed well-defined particles clearly separated from their surroundings, highlighting the technique's potential for particle identification. The findings highlight the need to combine effective sample pre-treatment with high-resolution chemical analysis to improve understanding of plastic fate in the environment and supporting future policy development or regulatory updates on plastic content in biosolids.

More Papers Like This

Article Tier 2

Chemical characterization of microplastics from biosolids: a comparison of FTIR and O-PTIR microspectroscopy

AI summary Read the abstract

Researchers compared conventional micro-FTIR and novel Optical Photothermal Infrared spectroscopy for chemical identification of microplastics in three biosolid sample types — wastewater treatment sludge, compost, and biofertilizer — after a multi-step cleanup procedure involving Fenton oxidation, cellulase enzyme degradation, density separation, and filtration. They identified six polymer types including PE, PS, PVA, PET, PVC, and PMMA, finding that O-PTIR outperformed micro-FTIR for smaller particles due to its 500 nm spatial resolution, while spectra from both methods were closely matched.

Article Tier 2

Chemical characterization of microplastics from biosolids: a comparison of FTIR and O-PTIR microspectroscopy

AI summary Read the abstract

Researchers compared conventional FTIR microspectroscopy with the emerging Optical Photothermal Infrared (O-PTIR) technique for chemical characterization and polymer-type identification of microplastics extracted from biosolids, finding that O-PTIR's submicron resolution and artifact-free spectra offer advantages over traditional methods.

Article

Advancing microplastic characterization in environmental samples using optical photothermal infrared (O-PTIR) spectroscopy

AI summary Read the abstract

This research applied machine learning algorithms to beach litter images from India's eastern coast, training classifiers to identify and categorize litter items from survey photographs. The ML-based approach demonstrated efficient litter classification at scale, offering a practical tool for national beach monitoring programs.

Article Tier 2

A method for the extraction of microplastics from solid biowastes including biosolids, compost, and soil for analysis by µ-FTIR

AI summary Read the abstract

Researchers developed and validated a method for extracting microplastics from solid organic materials including biosolids, compost, and soil for analysis by micro-FTIR spectroscopy. The approach combines wet peroxide oxidation with sequential density separations to isolate plastic particles from complex organic matrices. The method provides a reliable protocol for researchers studying how microplastics move through and accumulate in agricultural and waste management systems.

Article Tier 2

Two-dimensional Identification of Microplastics: Comparison of Optical Photothermal Infrared Spectroscopy with Fourier-Transform Infrared and Raman Spectroscopy

AI summary Read the abstract

Researchers compared optical photothermal infrared (O-PTIR) spectroscopy with conventional FTIR and Raman microspectroscopy for two-dimensional identification of microplastic particles. The study found that O-PTIR offers complementary capabilities to established techniques, with inter-system spectral comparisons demonstrating reproducibility across instruments.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper