We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Freshwater compartments: screening method for polymer identification and mass contents of microplastic particles using TED-GC-MS
AI summary Read the abstract
A fractionated filtration sampling system paired with TED-GC-MS analysis was developed as a harmonized method for screening microplastic polymer types and mass concentrations in freshwater bodies. The approach addresses the critical need for standardized sampling and analytical workflows that enable comparable microplastic data across different freshwater environments.
The pathways of plastics, especially of microplastic (MP), in environmental compartments, particularly in aquatic systems, are not well understood. The critical point is the lack of fast, harmonised methods for sampling, sample preparation and sample analysis. These three analytical steps are dependent on one another and must be optimised. In recent years, we developed a method for representative sampling and fast detection of MP in aqueous systems. The sampling in different freshwater bodies is performed in the field with a fractionated filtration system using mesh sizes of 500, 100 and 50 µm. For water with an intermediate or high content of suspended particular matter a minimum of 1000 L has to be filtered. In the lab, mesh sizes of 10 and 5 µm are used for further filtration. Subsequently, the water filtrates of the different particle size classes are sterilised, dried, weighed and homogenised, if necessary. Conventional methods for MP analysis are infrared and raman spectroscopy, giving information on the shapes and numbers of individually identified MP particles. Our focus is on the determination of mass contents of various polymers potentially contained in environmental samples. For qualitative and quantitative MP detection TED-GC-MS is used, a two-step method based on gas chromatography-mass spectrometry (GC-MS) with previous thermal extraction. This method not only enables us to screen the samples for characteristic marker-molecules, thus identifying single polymers, but furthermore allows the calculation of mass contents of individual polymers. In the present work, different freshwater compartments were exemplarily studied to identify containing polymers and calculate their mass content in MP particles.
More Papers Like This
Development and testing of a fractionated filtration for sampling of microplastics in water
AI summary Read the abstract
Researchers developed and tested a fractionated filtration system for sampling microplastics in water bodies, proposing a standardized sampling concept that accounts for plastic-specific properties to improve comparability of microplastic data across different studies and environments.
Decomposability versus detectability: First validation of TED‐GC/MS for microplastic detection in different environmental matrices
AI summary Read the abstract
Researchers validated TED-GC/MS as a fast microplastic detection method across different freshwater environmental matrices, finding that organic-rich sediments can affect polymer detectability and establishing matrix-specific limits of detection.
Microplastics’ analysis in water: Easy handling of samples by a new Thermal Extraction Desorption-Gas Chromatography-Mass Spectrometry (TED-GC/MS) methodology
AI summary Read the abstract
Researchers developed a simplified Thermal Extraction Desorption-GC/MS method for microplastic identification in water samples that processes the entire filter in a tubular furnace rather than requiring subsampling for thermogravimetric analysis. The approach reduced sample handling steps, minimized contamination risk, and maintained polymer identification accuracy comparable to standard methods.
Determination of microplastic mass content by thermal extraction desorption gas chromatography-mass spectrometry
AI summary Read the abstract
Researchers validated thermal extraction desorption gas chromatography-mass spectrometry (TED-GC-MS) as a rapid method for measuring the mass of microplastics in environmental samples. The technique can identify and quantify most common thermoplastic polymers in a single run, offering a faster alternative to labour-intensive visual counting methods.
Identification of Microplastics in Drinking Water Using Pyrolysis-GC/MS
AI summary Read the abstract
Researchers used pyrolysis-GC/MS to identify and quantify microplastics by polymer mass (rather than particle count) in drinking water samples. The method detected multiple polymer types and provided mass-based metrics that are more toxicologically relevant than particle counts commonly reported in water quality studies.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.