0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Policy & Risk Remediation Sign in to save

Hazardous air pollutants from the waste incineration industry : formation mechanisms, distribution characteristics, and potential environmental risks

HKBU Institutional Repository (Hong Kong Baptist University) 2020 Score: 30 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Chen Wang

Summary

This study investigated how hazardous air pollutants including dioxins, furans, and heavy metals are formed and distributed during industrial waste incineration. While focused on incineration emissions rather than microplastics directly, waste incineration is relevant to plastic waste management and the broader question of how plastics should be disposed of.

In this study, the formation mechanisms, distribution characteristics, and potential environmental risks of hazardous air pollutants from industrial-scale waste incineration processes were investigated. First, to clarify the dominant formation mechanism of polychlorinated dibenzo- p-dioxins and dibenzofurans (PCDD/Fs) in a hazardous waste (HW) incinerator, three tests were designed by adding different precursors in phenol-containing raw materials. With the addition of p-dichlorobenzene, PCDD/F levels at the quenching tower outlet were ten times higher than levels observed at the inlet. This indicates that the quenching tower failed to suppress the formation of PCDD/Fs and surface-mediated precursor reaction is the dominant formation mechanism in low-temperature stages. Besides, adsoprtive memory effect in air pollution control devices (APCDs) also led to high PCDD/F emissions. These findings suggest that to control PCDD/F emissions, strict regulation of chlorine contents in feed materials and frequent cleaning of APCDs are necessary. Meanwhile, single particles and solid residues were collected from the same HW incinerator. Morphologies and elemental compositions of particles in flue gas and indoor air were characterized by transmission electron microscopy-energy dispersive X-ray spectrometry (TEM-EDS). Eight types of single particles were classified, as organic, soot, K-rich, S-rich, Na-rich, Fe-rich, mineral and fly ash particles. The heavy metal partitioning behavior study suggested that Hg, Cd and Pb were mainly enriched in fly ash through evaporation, condensation, and adsorption; while Cr, Cu, Mn, and Ni were mostly remained in the bottom ash due to their low volatilities. In addition, the study also investigated environmental behaviors of certain characteristic pollutants. Thrity-two soil samples surrounding a cement plant co- processing HW were collected and analyzed for the presence of 16 polycyclic aromatic hydrocarbons (PAHs) and 12 heavy metals. Ten samples were selected for PCDD/Fs analysis. The highest concentration of PCDD/Fs occurred 1200 meters downwind from the cement plant. Levels of ∑16 PAHs ranged from 130.6 to 1134.3 μg/kg in soil. Source identification analysis suggested that the cement plant was the most likely source of PAH contamination. The concentrations of Cd and Hg were on average two times and six times higher than background values, respectively. Both incremental lifetime cancer risk model (ILCR) for PAHs and potential ecological risk index (RI) for heavy metals indicate potential risks to the population and the environment surrounding the cement plant. Last, to identify whether waste incineration is a major source for airborne environmentally persistent free radicals (EPFRs), tree leaf samples were collected from 120 sites surrounding four waste incinerators and one urban area. EPFR concentrations on leaves ranged from 7.5 × 10 16 to 4.5 × 10 19 spins/g. For the 10 N.D. samples, they were all collected from areas inaccessible by vehicles. Although previous work has linked atmospheric EPFRs to waste incineration, the evidence in this study suggests that vehicle emissions, especially from heavy-duty vehicles, are the main sources. According to our estimation, over 90% of the EPFRs deposited on tree leaves might be attributed to automotive exhaust emissions, as a synergistic effect of primary exhausts and degradation of aromatic compounds in road dust

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Quantification, characteristics, and distribution of microplastics released from waste burning furnaces and their associated health impacts

Researchers quantified microplastics released from waste burning furnaces in Indonesia, finding 41-77 fiber-type particles at sampling sites near each furnace, with an estimated 1.9-2.3 microplastics entering the human body via inhalation, highlighting an overlooked airborne exposure pathway.

Article Tier 2

Atmospheric microplastics emission from municipal solid waste incineration power plant: Field evidence and characterizations

Researchers detected microplastics for the first time in the exhaust gases of a municipal waste incinerator, finding over 2 trillion particles released into the air each year. The tiny particles, dominated by toxic polyvinyl chloride, can trap hazardous pollutants and travel far from the source, making industrial incineration a significant but previously overlooked pathway for microplastic pollution.

Article Tier 2

Microplastics as emerging contaminants in textile dyeing sludge: Their impacts on co-combustion/pyrolysis products, residual metals, and temperature dependency of emissions

Researchers studied how microplastics in textile dyeing sludge affect the pollutants released when the sludge is burned or heated for disposal. The presence of polyethylene and polypropylene microplastics increased the release of harmful gases and changed how toxic metals behaved during combustion. This means that microplastic-contaminated industrial waste can generate additional air pollution when disposed of through burning, adding to the pollutants people breathe.

Article Tier 2

Can incineration completely eliminate plastic wastes? An investigation of microplastics and heavy metals in the bottom ash and fly ash from an incineration plant

Researchers examined fly ash, bottom ash, and surface soil from a municipal solid waste incinerator for microplastics and heavy metals, finding that incineration did not completely eliminate plastics — with fibers persisting in fly ash — and that fly ash heavy metal concentrations exceeded safety thresholds in several categories.

Article Tier 2

Influence of operating parameters on the yield of micro-plastics from plastics incineration.

Researchers studied how different incineration conditions affect the yield and type of microplastics produced when plastics are burned, finding that temperature and oxygen levels significantly influence the output. The findings raise concerns that incomplete incineration of plastic waste — a common disposal method globally — can generate and release microplastics rather than eliminating them.

Share this paper