0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Remediation Sign in to save

Simultaneous measurements of microplastic 3D morphology and naphthalene adsorption based on digital holographic microscopy

Scientific Reports 2025 Score: 48 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Changqing Li, Yanan Zeng, Xiao Hu, Shiyu Wang, Xin Li, Jiyuan He, Renjie Yang, Haiyun Wu, Yanyan Wang

Summary

Researchers developed a digital holographic microscopy technique capable of simultaneously measuring the 3D morphology of microplastic particles and the concentration of naphthalene adsorbed onto them in situ. This dual-parameter approach enables more accurate study of how polycyclic aromatic hydrocarbons bind to microplastics in aquatic environments.

The accumulation of microplastics (MPs) in the body through biological cycles leads to persistent health risks owing to their degradation resistance. Enhanced toxicity arises from co-occurrence with polycyclic aromatic hydrocarbons (PAHs) that adsorb onto MPs in aquatic environments. Elucidation of MP-PAH adsorption mechanisms requires precise, simultaneous, in situ measurements of two critical parameters, i.e., the dynamic morphologies of MP particles and PAH concentrations. However, there is no comprehensive technology available that can simultaneously measure changes in both of these physical and chemical parameters. This report describes a digital holographic microscopy-based method for simultaneously measuring the 3D MP morphologies and PAH concentration changes in real time. A simple digital off-axis holographic microscopic system is used in combination with a phase difference method to measure the refractive index of the solution to determine the PAH concentration. The measurement results of the phase difference method are consistent with those obtained using a fluorescence spectrophotometer, and the signal-to-noise ratio is 38% higher. The developed technique enables real-time measurements of the PAH concentration changes to derive their adsorption kinetics, thermodynamics, and isothermal models, as verified by adsorption experiments involving various MPs in naphthalene solutions. This work presents a simple and purely optical method for simultaneous physical-chemical characterization in aqueous solutions, thus advancing measurement capabilities for analyzing environmental interfacial processes. The proposed methodology demonstrates broad applicability for co-monitoring morphological and chemical parameters in liquid-phase systems, which expands the scope of optical measurement techniques in biological and environmental sciences.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Simultaneous Measurements of Microplastic 3D Morphology and Naphthalene Adsorption Based on Digital Holographic Microscopy

Researchers used digital holographic microscopy to simultaneously measure microplastic particle morphology and naphthalene (a polycyclic aromatic hydrocarbon) adsorption in real time, providing a new tool for studying plastic-pollutant interactions in aquatic environments without disturbing the sample.

Article Tier 2

In-situ and real-time nano/microplastic coatings and dynamics in water using nano-DIHM: A novel capability for the plastic life cycle research

Researchers used a novel nano-digital inline holographic microscope to study nano- and microplastic particles in real time in water, revealing distinct coating patterns on particle surfaces and dynamic aggregation behaviors that standard offline methods miss.

Article Tier 2

Compact holographic microscope for imaging flowing microplastics

Researchers developed a compact holographic microscope capable of imaging flowing microplastics in aquatic environments, providing a fast, quantitative method for real-time characterization of plastic particle size and shape distributions.

Article Tier 2

In-situ and real-time detection of micro/nanoplastics in water: Combining laboratory experiments and modelling studies for plastic life cycle analysis

Researchers developed a nano-digital inline holographic microscope for real-time in-situ detection of micro- and nanoplastics in freshwater, combining laboratory experiments with modeling to analyze physicochemical characteristics and dynamic behaviors of MPs relevant to plastic life cycle analysis, addressing the 85% research gap between freshwater and marine MP studies.

Article Tier 2

Digital holographic microplastics detection and characterization in heterogeneous samples via deep learning

Researchers used digital holographic microscopy combined with deep learning to detect and characterize microplastic particles in heterogeneous samples containing algae, microorganisms, and other natural particles. This automated approach could improve the speed and accuracy of environmental microplastic monitoring.

Share this paper