0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Sign in to save

Analytical Method Development and Chemometric Approach for Evidencing Presence of Plasticizer Residues in Nectar Honey Samples

International Journal of Environmental Research and Public Health 2020 26 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 30 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Ivan Notardonato, Sergio Passarella, Giuseppe Ianiri, Cristina Di Fiore, Mario Vincenzo Russo, Pasquale Avino

Summary

Researchers detected phthalate plasticizers and bisphenol A — chemicals found in plastic materials — in commercial honey samples, raising concerns about food contamination from plastic packaging and production equipment. Honey is considered a sensitive indicator of environmental contamination, and finding plastic chemicals in it highlights the pervasiveness of plastic additive exposure through diet.

Over the years, anthropogenic sources have increasingly affected food quality. One of the most sensitive and nutritional matrices affected by chemical contamination is honey, due to the use of acaricides. Recently, the attention has moved to the presence of phthalates (PAEs) and bisphenol A (BP-A), molecules present in plastic materials used both in the production phase and in the conservation of honey. In this study, an analytical method for the simultaneous determination of PAEs (dimethyl phthalate DMP, diethyl phthalate DEP, diisobutyl phthalate DiBP, dibutyl phthalate DBP, bis(2-ethylhexyl) phthalate DEHP, and di-n-octyl-phthalate DnOP) and BP-A was developed. The extraction technique is the ultrasound-vortex-assisted dispersive liquid–liquid microextraction (UVA-DLLME), using 150 µL of toluene as an extraction solvent, followed by the gas chromatography coupled with ion trap mass spectrometry analysis (GC–IT/MS). The developed method is sensitive, reliable, and reproducible: it shows high correlation coefficients (R > 0.999); limits of detection (LODs) less than 11 ng·g−1; limits of quantification (LOQs) less than 16 ng·g−1; repeatability below 3.6%, except BP-A (11.6%); and accuracy below 4.8%, except BP-A (17.6%). The method was applied to 47 nectar honey samples for evidencing similarities among them. The chemometric approach based on Hierarchical Cluster Analysis and Principal Component Analysis evidenced some similitudes about sample origin as well as marked differences between PAE and BP-A sources.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

From Environment to Hive: Plasticizer and Bisphenols Contamination in Algerian Honeys

Scientists tested honey from different regions of Algeria and found that every single sample contained harmful chemicals from plastics, including substances that can disrupt hormones in the human body. The most concerning finding was that levels of bisphenol A (BPA) - a chemical linked to health problems - were high enough to potentially pose risks to people who eat the honey regularly. This research shows how plastic pollution is contaminating even natural foods like honey, which could affect human health through our diet.

Article Tier 2

Honey Quality and Microplastic Migration from Food Packaging: A Potential Threat for Consumer Health?

Researchers investigated the potential for microplastic migration from plastic food packaging into honey products, reviewing evidence that storage containers can release microplastic and nanoplastic particles into this widely consumed food, posing potential consumer health concerns.

Article Tier 2

Detection and degradation of bisphenols in honey using matrix-induced dispersive liquid-liquid microextraction: Insights into the release of bisphenol A from polycarbonate microplastics

Researchers developed a matrix-induced dispersive liquid-liquid microextraction method to detect and degrade bisphenols (BPs) in honey and investigated the release of BPs from microplastics into honey. The method successfully identified BP contamination and showed that microplastics can leach bisphenols into food matrices, posing risks to honeybee health.

Article Tier 2

Microplastic Migration from Plastic Packaging into Honey

Researchers tested honey from flexible plastic pouches under dry outdoor and refrigeration storage conditions, finding direct evidence that microplastics migrate from the packaging into the honey, contaminating a product traditionally prized for its purity.

Article Tier 2

Honey as a bioindicator of microplastic pollution: insights from industrial and special honey types

Researchers analyzed industrial and artisanal honeys from Türkiye for microplastic contamination using microscopy and FTIR spectroscopy. Microplastics were detected in 93% of samples, with industrial honeys containing higher concentrations than artisanal varieties, suggesting that processing and packaging contribute to contamination. The study estimates daily microplastic intake from honey consumption and highlights honey as a useful bioindicator of environmental microplastic pollution.

Share this paper