0
Article Tier 2 Food & Water Remediation Sign in to save

Conventional and biological treatment for the removal of microplastics from drinking water

Chemosphere 2021 101 citations

AI summary Read the abstract

Researchers examined microplastic removal by a full-scale drinking water treatment plant, finding that conventional coagulation-flocculation-filtration processes and biological filters with granular activated carbon effectively reduced microplastic concentrations in treated water.

Polymers
Study Type Environmental

This study examines the removal of microplastics and other anthropogenic particles (>10 μm) from surface water by a full-scale conventional drinking water treatment plant. The treatment process is composed of coagulation with aluminum hydroxide, flocculation, anthracite-sand filtration, and chlorination. Samples were also collected from pilot-scale biological filters consisting of anthracite-sand or granular activated carbon (GAC) media operated with or without pre-ozonation and at a range of different empty-bed contact times (EBCTs). Particles in 10 L water samples collected in duplicate using a fully enclosed sampling apparatus were separated using sieves with 500 μm, 300 μm, 125 μm, and 45 μm openings followed by filtration through 10 μm polycarbonate filters. Particles were counted using stereomicroscopy and characterized using μ-Raman spectroscopy. Full-scale conventional treatment removed 52 % of anthropogenic particles when comparing raw (42 ± 18 particles/L) and finished water (20 ± 8 particles/L). Coagulation, flocculation, and sedimentation accounted for the highest removal (70 %) of any individual unit process. Overall removal was reduced to 52 %, the difference being attributed to airborne particle deposition that occurred while water was detained in a clearwell (exposed to atmosphere via ventilation) that was used to achieve the required contact time for disinfection. The majority of the particles (>80 %) were identified as fibers 10-45 μm; microplastics were predominantly composed of polyester while the non-plastic anthropogenic particles were primarily cellulose. None of the pilot filter configurations examined resulted in significantly fewer microplastics when compared to full-scale conventional filtration. This study illustrates that the removal efficiency of conventional treatment may be limited when considering microfibers <45 μm in size.

More Papers Like This

Article Tier 2

Occurrence and removal of microplastics by advanced and conventional drinking water treatment facilities

AI summary Read the abstract

Researchers assessed microplastic occurrence and removal efficiency at drinking water treatment plants using both conventional and advanced treatment processes. Advanced treatment steps such as ultrafiltration and activated carbon significantly improved microplastic removal compared to conventional coagulation and filtration alone.

Article Tier 2

Fate of microplastics in the drinking water production

AI summary Read the abstract

Researchers tracked the fate of microplastics through drinking water treatment processes, finding that conventional treatment steps like coagulation, sedimentation, and filtration removed the majority of microplastics but did not eliminate them entirely.

Article Tier 2

Contamination and Removal Efficiency of Microplastics and Synthetic Fibres in a Conventional Drinking Water Treatment Plant

AI summary Read the abstract

Researchers found that a conventional drinking water treatment plant in Geneva removed the majority of microplastics from raw water, with coagulation and sand filtration contributing most to removal, though some particles persisted through to finished drinking water.

Article Tier 2

Occurrence and removal of microplastics by advanced and conventional drinking water treatment facilities

AI summary Read the abstract

Researchers evaluated the performance of both advanced and conventional drinking water treatment processes for removing microplastics, finding that advanced methods such as ultrafiltration substantially outperform standard coagulation and filtration. Most conventional treatment plants leave a meaningful fraction of microplastics in finished drinking water.

Article Tier 2

Efficient removal of microplastics through a combined treatment process: Pre-filtration and adsorption

AI summary Read the abstract

A combined treatment process integrating coagulation, sedimentation, and filtration achieved efficient removal of microplastics from drinking water. The study supports the feasibility of adapting existing water treatment infrastructure to address microplastic contamination.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper