0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Food & Water Nanoplastics Remediation Sign in to save

Using Infrared Photothermal Heterodyne Imaging to Characterize Micro- and Nanoplastics in Complex Environmental Matrices

Environmental Science & Technology 2021 37 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 40 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Kirill Kniazev, Ilia M. Pavlovetc, Shuang Zhang, Junyeol Kim, Robert Louis Stevenson, Kyle Doudrick, Masaru Kuno

Summary

Researchers introduced infrared photothermal heterodyne imaging (IR-PHI) as a 300 nm resolution technique for identifying and quantifying micro- and nanoplastics in complex environmental matrices, demonstrating its application to nylon tea bag leachates and sediment samples.

Polymers

A key challenge for addressing micro- and nanoplastics (MNPs) in the environment is being able to characterize their chemical properties, morphologies, and quantities in complex matrices. Current techniques, such as Fourier transform infrared spectroscopy, provide these broad characterizations but are unsuitable for studying MNPs in spectrally congested or complex chemical environments. Here, we introduce a new, super-resolution infrared absorption technique to characterize MNPs, called infrared photothermal heterodyne imaging (IR-PHI). IR-PHI has a spatial resolution of ∼300 nm and can determine the chemical identity, morphology, and quantity of MNPs in a single analysis with high sensitivity. Specimens are supported on CaF2 coverslips under ambient conditions from where we (1) quantify MNPs from nylon tea bags after steeping in ultrapure water at 25 and 95 °C, (2) identify MNP chemical or morphological changes after steeping at 95 °C, and (3) chemically identify MNPs in sieved road dust. In all cases, no special sample preparation was required. MNPs released from nylon tea bags at 25 °C were fiber-like and had characteristic IR frequencies corresponding to thermally extruded nylon. At 95 °C, degradation of the nylon chemical structure was observed via the disappearance of amide group IR frequencies, indicating chain scission of the nylon backbone. This degradation was also observed through morphological changes, where MNPs altered shape from fiber-like to quasi-spherical. In road dust, IR-PHI analysis reveals the presence of numerous aggregate and single-particle (<3 μm) MNPs composed of rubber and nylon.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Photothermal Heterodyne Imaging of Micron Sized Objects

Researchers tested a sensitive imaging technique called photothermal heterodyne imaging to detect and visualize micron-sized polymer beads similar in size to microplastic particles. The method shows promise as a non-destructive way to detect and characterize small plastic particles in various environments.

Article Tier 2

Characterization of microplastics in tap water by optical photothermal infrared

Researchers used optical photothermal infrared spectroscopy to characterize microplastics in tap water, identifying particles as small as a few micrometers that conventional FTIR techniques cannot resolve. The higher detection sensitivity revealed that microplastic concentrations in drinking water are likely underestimated by standard methods.

Article Tier 2

Identifying Microplastics in Laboratory and Atmospheric Aerosol Mixtures via Optical Photothermal Infrared and Raman Microspectroscopy

Researchers developed optical photothermal infrared spectroscopy methods to identify microplastics in both laboratory-prepared and real atmospheric aerosol samples, demonstrating the technique's ability to distinguish plastic particles from other aerosol components in complex air quality monitoring contexts.

Article Tier 2

Chemical characterization of microplastics from biosolids: a comparison of FTIR and O-PTIR microspectroscopy

Researchers compared conventional FTIR microspectroscopy with the emerging Optical Photothermal Infrared (O-PTIR) technique for chemical characterization and polymer-type identification of microplastics extracted from biosolids, finding that O-PTIR's submicron resolution and artifact-free spectra offer advantages over traditional methods.

Article Tier 2

Short-wave infrared hyperspectral imaging of microplastics: Effects of chemical and physical processes on spectral signatures and detection capabilities

Researchers evaluated short-wave infrared hyperspectral imaging for rapid microplastic detection and polymer identification, testing the effects of various physical and chemical weathering agents on spectral signatures and finding the technique effective for identifying multiple polymer types in complex samples.

Share this paper