Development and testing a low-cost device for airborne PM monitoring in highly anthropized areas: The international maritime hub of Civitavecchia (Rome, Italy)

Geosystems and Geoenvironment 2022 3 citations

AI summary Read the abstract

Researchers developed a low-cost particulate matter monitoring device combining an optical counter with filter collection, deploying it at an Italian maritime port where analysis revealed microplastics and textile fibers among airborne particles alongside mineral dust and carbon from shipping activities.

In this paper we describe our work aimed at designing a system able to measure the particulate matter (PM) concentrations via an optical particle counter (OPC) and simultaneously collect it via standard 2.5 cm filters for laboratory characterization. The Port of Civitavecchia (Italy), one of the most important maritime hubs of the Mediterranean Sea, was selected as a test site for an eight-months monitoring campaign. Comparison between the data provided by our device with those from the referenced and certified monitoring stations from the governmental Regional Agency for the Protection of the Environment (ARPA Lazio) allowed to define clear threshold values (PM10 = 25 μg/m3 and PM2.5 = 10 μg/m3). These threshold values need to be considered when correcting the OPC raw data with respect to the humidity (RH) conditions. The sample material was characterized through optical microscopy and SEM-EDS (scanning electron microscopy coupled with energy-dispersive X-ray fluorescence) and spectroscopy (FTIR, Raman), showing a variegate composition from Al-Fe-oxides to silicates, carbonates, and sulfates, to coal and amorphous carbon together with microplastics and textile fibers. As a final test, we analyzed the PM trends provided by our device during the COVID-19 lockdown, when stringent restrictions in the human activities caused well-known fluctuations in the atmospheric pollution. We again observed an evolution of the PM peaks in excellent agreement with the results yielded by the ARPA Lazio monitoring stations. This result provides a valuable confidence test for our devices highlighting the effectiveness of the presented strategy for airborne particulate-matter monitoring.

More Papers Like This

Article Tier 2

Air pollution assessment using a cost-effective device: the case study of the northern Latium coastal area.

AI summary Read the abstract

Researchers used a cost-effective sensor network to monitor air pollution in a coastal area of northern Lazio, Italy, finding elevated particulate matter concentrations linked to traffic and industrial sources. While focused on air quality rather than microplastics, airborne particulate monitoring is increasingly important for tracking atmospheric microplastic exposure in urban and coastal areas.

Article Tier 2

Outdoor Microplastic Analysis Using Inlet Filters from an NOx Regulatory Air Quality Monitoring Device

AI summary Read the abstract

Atmospheric microplastics were analyzed from 10 months of continuous inlet filter samples collected as part of routine NOx air quality monitoring in Hull, UK, providing size and composition data for urban atmospheric plastic particles. The study demonstrates that existing regulatory air quality monitoring infrastructure can be repurposed for ambient microplastic surveillance.

Article Tier 2

Port-driven coupling of carbonaceous aerosols and airborne microplastics in a coastal city

AI summary Read the abstract

Researchers studying air near a busy port city in Mexico found that soot-like pollution particles and tiny airborne microplastic fibers tend to show up together in the air people breathe, likely both coming from port and ship activity. This matters because it suggests that living near ports may mean inhaling not just traditional pollution, but also a steady stream of microplastic fibers alongside it — a combined exposure that current air quality monitoring often overlooks.

Article Tier 2

In-Situ Towed Sampling Device for Integrated Calibration and Monitoring of Surface Water Microplastics

AI summary Read the abstract

This study developed a prototype in-situ towed sensor device for real-time measurement of microplastic concentrations at the ocean surface, using optical particle detection to monitor spatial distribution during ship surveys. Low-cost in-situ sensors can dramatically increase the geographic coverage of microplastic monitoring compared to traditional bottle sampling methods.

Article Tier 2

Simultaneous Measurement and Compositional Analysis of Atmospheric Microplastics in Taiwan Utilizing Optical and Chemical Methods

AI summary Read the abstract

Researchers measured airborne microplastics across three sites in Taiwan — rural, near a waste incinerator, and in a traffic-heavy area — finding the highest concentrations at the traffic site, with polyethylene and polypropylene as the dominant plastic types. Estimated daily human exposure through breathing and accidental ingestion ranged in the tens of particles per kilogram of body weight, underscoring that air is a significant but often overlooked route of microplastic exposure.