We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Transport behavior of nanoplastics in activated carbon column
AI summary Read the abstract
Researchers investigated the transport and retention of nanoplastics through granular activated carbon columns used in drinking water treatment. Nanoplastics were partially retained in activated carbon but their behavior depended on particle surface charge and solution chemistry, with implications for drinking water safety.
Nanoplastics can be produced directly from some artificial products, such as cosmetics, or indirectly from the breakup of large pieces of plastic waste. They have a small particle size, large specific surface area, and stable structure and can concentrate toxic compounds in water. The discharge of nanoplastics into the water environment through urban piping systems or surface runoff may lead to the contamination of surface water resources, which poses a great threat to the safety of drinking water. As a common adsorbent, granular activated carbon (GAC) is widely used in the advanced treatment of drinking water. However, most of the studies focused on the transport ability of nanoplastics in quartz sand, and there is a lack of research on the migration behavior of nanoplastics in activated carbon media. In this study, the stability and pore characteristics of GAC were studied, and its regeneration efficiency was investigated. The transport curves of PSNPs, which have a particle size of 98 ± 9 nm and specific surface area of about 67 m/g, were compared under different ionic strengths, ionic species, flow rates, pH, and humic acid (HA) concentrations. And DLVO theory was used to analyze the transport behavior of nanoplastics in activated carbon column. All experiments were performed at room temperature to make the results generalizable. The results showed that GAC had stable pore structure and excellent adsorption capacity. The surface area and pore volume of GAC are 759 m/g and 0.357 cm/g, respectively. And the regeneration rate of GAC can reach 90% and 83.3% after the first two regeneration cycles. On the other hand, at high ionic strength and low pH, the repulsive barrier between PSNPs and activated carbon gradually disappeared; then, more PSNPs were deposited in the activated carbon media, and the concentration of PSNPs in the effluent water was lower. Both the flow rate and HA promoted the transport of PSNPs, but the breakthrough curves of PSNPs did not change significantly when the HA concentration was further increased. At the same ion concentration, PSNPs tend to deposit on the surface of activated carbon in the background solution of Ca compared with Na. This study reveals the migration mechanism of PSNPs in the activated carbon filter column, which is of great importance to ensure the safety of drinking water and human health.
More Papers Like This
Paving roads with recycled plastics: Microplastic pollution or eco-friendly solution?
AI summary Read the abstract
This study assessed the capability of granular activated carbon filtration to remove nanoplastics from drinking water, finding approximately 85% removal efficiency for particles below 1 micrometer. Removal was lower for smaller, hydrophilic particles that resist adsorption.
Retention and Transport of Nanoplastics with Different Surface Functionalities in a Sand Filtration System
AI summary Read the abstract
This study tested how well sand filtration removes nanoplastics with different surface chemistries — a key question since nanoplastics are increasingly detected in drinking water sources. Surface charge strongly influenced whether nanoplastics were retained or passed through the filter, with negatively charged particles being harder to remove.
Removal of nanoparticles (both inorganic nanoparticles and nanoplastics) in drinking water treatment – coagulation/flocculation/sedimentation, and sand/granular activated carbon filtration
AI summary Read the abstract
Researchers reviewed the removal of inorganic nanoparticles and nanoplastics during conventional drinking water treatment, finding that coagulation/flocculation/sedimentation and sand/granular activated carbon filtration can substantially reduce nanoparticle concentrations but with variable efficiency depending on particle type.
Norfloxacin removal efficiency by a carbon filtration column under the influence of nanoplastics: mechanistic analysis and prediction model
AI summary Read the abstract
Researchers designed experiments to examine how nanoplastics influence norfloxacin removal efficiency in activated carbon filtration columns used in drinking water treatment, developing a mechanistic analysis and predictive model for antibiotic leakage risk when nanoplastics act as carriers in the filtration system.
Nanoplastics adsorption and removal efficiency by granular activated carbon used in drinking water treatment process
AI summary Read the abstract
Researchers tested granular activated carbon used in drinking water treatment for its ability to adsorb polystyrene nanoplastics, finding efficient removal in both ultrapure water and surface water from Lake Geneva, with adsorption following Langmuir isotherm behavior.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.