Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Human Health Effects Marine & Wildlife Policy & Risk Remediation Sign in to save

Solving urban water microplastics with bacterial cellulose hydrogels: Leveraging predictive computational models

Chemosphere 2022 24 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Ivana Mendonça, Jessica Sousa, César Cunha, Marisa Faria, Artur Ferreira, Nereida Cordeiro

Summary

Researchers developed bacterial cellulose hydrogels from membrane remnants as sustainable bioflocculants for removing microplastics from urban water, using computational models to predict and optimize removal efficiency under varying conditions.

Study Type Environmental

The prevalence of microplastics (MPs) in both urban and aquatic ecosystems is concerning, with wastewater treatment plants being considered one of the major sources of the issue. As the focus on developing sustainable solutions increases, unused remnants from bacterial cellulose (BC) membranes were ground to form BC hydrogels as potential bioflocculants of MPs. The influence of operational parameters such as BC:MPs ratio, hydrogel grinding, immersion and mixing time, temperature, pH, ionic strength, and metal cations on MPs flocculation and dispersion were evaluated. A response surface methodology based on experimental data sets was computed to understand how these parameters influence the flocculation process. Further, both the BC hydrogel and the hetero-aggregation of MPs were characterised by UV-Vis, ATR-FTIR, IGC, water uptake assays, fluorescence, and scanning electron microscopy. These highlights that the BC hydrogel would be fully effective at hetero-aggregating MPs in naturally-occurring concentrations, thereby not constituting a limiting performance factor for MPs' optimal flocculation and aggregation. Even considering exceptionally high concentrations of MPs (2 g/L) that far exceed naturally-occurring concentrations, the BC hydrogel was shown to have elevated MPs flocculation activity (reaching 88.6%: 1.77 g/L). The computation of bioflocculation activity showed high reliability in predicting flocculation performance, unveiling that the BC:MPs ratio and grinding times were the most critical variables modulating flocculation rates. Also, short exposure times (5 min) were sufficient to drive robust particle aggregation. The microporous nature of the hydrogel revealed by electron microscopy is the likely driver of strong MPs bioflocculant activity, far outperforming dispersive commercial bioflocculants like xanthan gum and alginate. This pilot study provides convincing evidence that even BC remainings can be used to produce highly potent and circular bioflocculators of MPs, with prospective application in the wastewater treatment industry.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Advancing bacterial cellulose biopolymers & hydrogels to remediate microplastic pollution

Researchers developed bacterial cellulose biopolymers and hydrogels as biodegradable alternatives to fossil-fuel-based filters for removing microplastics from wastewater, optimizing operational parameters using response surface methodology. Results showed removal efficiencies of up to 99% for concentrated MP suspensions, with flow cytometry, electron microscopy, and ATR-FTIR confirming the flocculation mechanism and the potential for large-scale industrial application.

Article Tier 2

Efficacy of bacterial cellulose hydrogel in microfiber removal from contaminated waters: A sustainable approach to wastewater treatment

Researchers developed a bacterial cellulose hydrogel made from unused cellulose remnants and tested it as an eco-friendly filter for removing microfibers from contaminated water. The hydrogel achieved an average removal rate of nearly 94 percent and retained the captured fibers well, releasing only about 8 percent after washing. The study presents this bio-based approach as a sustainable and effective alternative for tackling microfiber pollution in wastewater.

Article Tier 2

Bacterial cellulose biopolymers: The sustainable solution to water-polluting microplastics

Researchers developed bacterial cellulose (BC) biopolymer filters as a sustainable alternative to petroleum-based polymer filters used in wastewater treatment plant microplastic removal. BC filters showed high MP capture efficiency and are biodegradable, addressing both microplastic pollution and the environmental costs of conventional synthetic filter maintenance.

Article Tier 2

Tailored cellulose-based flocculants for microplastics removal: Mechanistic insights, pH influence, and efficiency optimization

Researchers developed plant-derived (cellulose-based) flocculants that clump microplastics together so they can be more easily removed from water, finding that a low concentration of 0.001 g/mL was optimal and that both electrical charge and water-repelling interactions drive the process depending on the type of plastic.

Article Tier 2

Design of model microplastics to study their transport in urban waters

Researchers designed model microplastic particles with controlled physical properties to systematically study their transport behavior in urban water systems. The work provides a foundation for understanding how microplastic size, density, and shape influence fate and transport in stormwater and urban drainage networks.