We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Treatment of laundry wastewater using extracellular polymeric substances (EPS)
Summary
Researchers developed an eco-friendly treatment for commercial laundry wastewater using bacterial extracellular polymeric substances as a bio-flocculant, achieving up to 98% turbidity removal and 88% chemical oxygen demand reduction when combined with alum, offering a greener alternative to conventional chemical treatment.
Abstract The problem of management and treatment of wastewater from commercial laundries is a matter of concern. The present study provides an effective and eco-friendly solution to the treatment of wastewater from commercial laundries in Quebec (Canada) by using the extracellular polymeric substance (EPS) as a bio-flocculant. EPS was produced from the valorization of crude glycerol and paper mill sludge by a bacterial strain (BS-04). Two different types of EPS: Slime EPS (S-EPS) and Broth EPS (B-EPS) were used for the treatment of commercial laundry wastewater (CLWW). This is the first study for the treatment of CLWW using bio-flocculant EPS. A comparison between the conventional treatment of laundry wastewater (LWW) by chemical coagulants (FeSO 4 , CaCl 2 , Alum) and enhanced treatment by bio-flocculant EPS has been drawn in the study. Moreover, LWW treatment by a combination of EPS and chemical coagulants was also investigated. It was observed that S-EPS (0.6 g/L) gave better flocculation activity (FA) than B-EPS. S-EPS alone can remove 83.20% of turbidity, 77.69% of suspended solids (SS), and 76.37% of chemical oxygen demand (COD). The best results were obtained by combining S-EPS (0.6 g/L) with alum (300 mg/L) at pH 7 for a treatment time of 30 min. This combination was able to remove 98% of turbidity, 95.42% of SS, and 83.08% of COD from LWW. When treatment time has been increased to 4 h at pH 7, it resulted in more than 88% COD removal from CLWW. Graphical Abstract
Sign in to start a discussion.
More Papers Like This
Researchon the removal of chemical oxygen demand and surfactants in commercial laundry wastewater by coagulation-flocculation process
Researchers investigated coagulation-flocculation treatment of commercial laundry wastewater, which contains significantly higher chemical oxygen demand (COD) and surfactant concentrations than domestic wastewater. Jar test experiments showed that poly aluminium chloride (PAC) at pH 7 and 60 mg/L dosage outperformed FeSO4·7H2O in reducing COD and surfactants to discharge standards.
Microplastics removal from water body by extracellular polymeric substances (EPS) extracted from microalge through surfactants pre-treatment
Researchers explored using extracellular polymeric substances extracted from microalgae — combined with surfactant pretreatment — to remove microplastics from water. The biological approach showed promise as a low-cost and environmentally friendly alternative to conventional filtration methods.
Removal of Microplastics from Laundry Wastewater Using Coagulation and Membrane Combination: A Laboratory-Scale Study
Researchers characterized microplastics in raw domestic laundry wastewater (9,000–11,000 particles/L, dominated by polyester fibers) and tested whether combining coagulation with ultrafiltration membrane filtration improved MP removal. The combined process significantly enhanced removal compared to coagulation alone, highlighting laundry wastewater as a major MP source amenable to treatment at scale.
The Role of Extracellular Polymeric Substances in Micropollutant Removal
This review examines the role of extracellular polymeric substances (EPS) in biological wastewater treatment systems, focusing on how EPS affect micropollutant removal and microbial aggregate structure. The authors find that EPS can act as a protective barrier for microbial communities under toxic conditions and may play an important role in sequestering pharmaceutical and pesticide micropollutants.
Effect of coagulation on microfibers in laundry wastewater
Researchers tested ferric chloride and polyaluminium chloride (PACl) as coagulants for removing synthetic microfibers from laundry wastewater, finding that surfactants in detergent reduced removal efficiency from up to 96% to 0-37%. Adding PACl restored removal to above 90%, with optimal PACl concentrations dependent on detergent concentration, suggesting coagulant addition is critical for effective microfiber removal from laundry effluent.