We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Nile Red staining for nanoplastic quantification: Overcoming the challenge of false positive counts due to fluorescent aggregates
AI summary Read the abstract
Researchers expanded the Nile Red staining method to quantify nanoplastics smaller than 1 µm, identifying fluorescent aggregates as a source of false positive counts and developing methodological corrections to overcome this challenge and improve the accuracy of nanoplastic detection in environmental samples.
The true extent of plastic particle pollution is largely unknown, particularly for particles <1 µm (na-noplastics), as they are difficult to detect. Here, we expand the Nile Red (NR) staining approach often used to visualize microplastics to the quantification of nanoplastics. Using NR staining for nanoplastic quantification is largely unexplored due to the formation of fluorescent NR aggregates which cause false positive counts in single particle counting. Here, we study the number and size of the NR aggregates formed as a function of NR concentration and show that with decreasing NR concentration, the number and size of the NR aggregates drop. At nanomolar concentrations, the number of NR aggregates is low, while staining of nanoplastics at these concentrations still results in signals that are sufficiently bright for single particle detection. To challenge and verify our ap-proach, we spiked a drinking water sample with known amounts of nanoplastics. After quantifica-tion of the total amount of NR positive particles and considering NR aggregates and the added amounts of nanoplastics, we find a stable number of NR positive particles for the drinking water sample, thus verifying our approach. To demonstrate the direct applicability of our method, with-out any pre-analytical treatment, we determined the number of NR positive particles in different drinking water samples. In water obtained from plastic bottles and plastic-lined cartons, we detect-ed approximately 250 particles/nL, which is well above the level of detection of our method. In tap water, we found approximately 10 times fewer NR positive nanoparticles. Our study demonstrates that staining at nM NR concentrations combined with a careful characterization of the number of NR aggregates in solution allows for using single-particle counting for nanoplastic quantification in water samples. We foresee that this approach can contribute to filling the gap in knowledge on the abundance of nanoplastics.
More Papers Like This
Nile Red staining for nanoplastic quantification: Overcoming the challenge of false positive counts due to fluorescent aggregates
AI summary Read the abstract
Researchers refined a Nile Red dye-based method to count nanoplastic particles in water by reducing dye concentration to near-nanomolar levels, minimizing false positives from dye aggregates that mimic plastic particles. Using this approach they detected approximately 250 nanoplastics per nanoliter in water from plastic bottles and cartons — roughly ten times more than in tap water.
Modification of fluorescence staining method for small-sized microplastic quantification: Focus on the interference exclusion and exposure time optimization
AI summary Read the abstract
Researchers optimized a Nile Red/DAPI fluorescence co-staining method for quantifying small microplastics, identifying key interference factors and exposure time parameters that significantly improve accuracy of microplastic detection.
Identification and quantification of microplastics using Nile Red staining
AI summary Read the abstract
Researchers tested Nile Red staining as a method for identifying and quantifying microplastics in environmental samples, finding it useful for rapid screening but noting limitations in distinguishing plastics from non-plastic particles.
Separation and flow cytometry analysis of microplastics and nanoplastics
AI summary Read the abstract
Researchers improved a flow cytometry method for counting and separating microplastics and nanoplastics stained with a fluorescent dye called Nile Red. By adjusting the chemical solution used in detection, they reduced particle clumping and improved measurement accuracy for plastic particles across a range of sizes. The refined technique offers a faster and more reliable way to quantify plastic pollution in environmental and biological samples.
A rapid-screening approach to detect and quantify microplastics based on fluorescent tagging with Nile Red
AI summary Read the abstract
Researchers developed a rapid fluorescent screening method using Nile Red dye to detect and quantify microplastics in environmental samples, finding it significantly faster than conventional methods while maintaining reasonable accuracy.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.