0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Remediation Sign in to save

Advancing water treatment sustainability: Investigating electrified Ti3C2T composite membranes for minimizing microplastic fouling

Chemosphere 2023 20 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 45 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Mariam Ouda, Ravi P. Pandey, Fawzi Banat, Shadi W. Hasan

Summary

Researchers developed electrified composite membranes using sulfonated polyethersulfone and MXene (Ti3C2T) to reduce microplastic fouling in ultrafiltration systems, finding that applying an electric field significantly reduced plastic particle adhesion to the membrane surface. The approach offers a promising strategy for maintaining membrane performance in water treatment plants handling microplastic-contaminated water.

Polymers
Study Type Environmental

The overuse of plastics has led to a large influx of microplastics (MPs) in water bodies and water/wastewater treatment plants. Coupled with the ongoing water crisis, this poses a threat to freshwater availability as MPs disrupt the operation of these plants. MPs cause severe fouling of low-pressure membrane technologies such as ultrafiltration (UF) due to the strong adhesion between MPs and the membrane surface. An electrified membrane-based technology is suggested as an alternative MP fouling mitigation strategy. In this study, composite membranes of sulfonated polyethersulfone (SPES)/MXene (TiCT) were fabricated and evaluated as a promising candidate for mitigating fouling of MPs. The described SPES/TiCT composite membrane was designed to improve important physiochemical properties such as conductivity without affecting water flux. The membranes were tested under different electrical potentials to find an optimal strategy to reduce MP fouling. The performance tests showed that the flux increased from 42 L m. h at 0 V to 49 L m. h at 2 V due to electrostatic repulsion when 5 wt% TiCT was used as a result of the applied electric potential. In addition, it was shown that intermittent applied voltage using "30 min ON: 60 min OFF" mode resulted in more stable water flux due to in-situ coagulant formation and cleaning. This study illustrates the potential of MXene-based membranes for mitigating MP fouling and paves the way for future research on membrane materials that can enhance system performance.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Electrified membranes for microplastic fouling mitigation

This study explored electrified membranes as a solution to the severe fouling of water treatment membranes caused by microplastics. Applying electrical current to membranes can repel negatively charged microplastics, reducing clogging and improving the efficiency of microplastic removal from drinking water.

Article Tier 2

Performance of Electrified MXene Membranes in Real Wastewater Applications

Researchers investigated the performance of electrified MXene-based membranes for nanoplastic removal from real wastewater, finding that applying an electric field significantly improved nanoplastic rejection through electrostatic repulsion and electrocoagulation mechanisms while also increasing water flux compared to non-electrified conditions.

Article Tier 2

An assessment of the impact of structure and type of microplastics on ultrafiltration technology for microplastic remediation

Researchers assessed ultrafiltration technology for microplastic removal from water, finding that membrane performance varied based on microplastic structure, size, and polymer type, with implications for optimizing tertiary treatment in water purification systems.

Article Tier 2

Membrane fouling characteristics and mechanisms in coagulation-ultrafiltration process for treating microplastic-containing water

This study investigated how microplastics affect membrane fouling during a common water treatment process that combines coagulation with ultrafiltration. Researchers found that while microplastics initially worsen membrane fouling, adding the right amount of coagulant can actually turn the plastics into an advantage by creating a looser filter cake that improves water flow.

Article Tier 2

Fate and Behavior of Microplastics in Ultrafiltration Membrane Systems for Water Treatment: Fouling, Releasing, and Organic Leaching

Researchers investigated the fate and behavior of microplastics in ultrafiltration membrane systems used for water treatment, examining three key phenomena: membrane fouling caused by microplastic deposition, release of microplastics through membrane failure or bypass, and leaching of organic additives from microplastics. The work provides mechanistic understanding of how microplastics interact with ultrafiltration systems in drinking water treatment contexts.

Share this paper