New Acrylate Co-Polymer Membrane Synthetized by Photo-Polymerization Technique for Lead (II) Ion-Selective Electrode
Summary
Researchers synthesized a novel p(THFA-co-HEMA) acrylate co-polymer membrane via photo-polymerization and developed it into a lead(II) ion-selective electrode (Pb-ISE). The sensor demonstrated a detection range from 0.1 to 10-6 M with a LOD of 7.59 x 10-7 M, a response time of 6.7 seconds, and validation results equivalent to AAS standard methods for real environmental water and sediment samples.
A novel p(THFA-co-HEMA) membrane based on acrylate CP was successfully synthesized through PP technique, and applied into Pb-ISE (Pb-ISE). THFA optimum composition was HEMA 9:1 (TH91), with a Tg of -6.5 o C. The structure of p(THFA-co-HEMA) was characterized using FTIR. The Pb-ISE sensor showed remarkable calibration measurement in the range from 0.1 to 10 -6 M, with a LOD of 7.59 x 10 -7 M, and it has obeyed a Nernstian number of 30.5 mV/dec. In addition, the fabricated Pb-ISE sensors showed fairly good selectivity coefficients of several types of ions, such as K + (-6.53 0.11), Na + (-6.35 0.16), NH4 + (-6.76 0.11), Mg 2+ (-12.15 0.13), Ca 2+ (12.12 0.14), Cu 2+ (-4.33 0.11) and Cd 2+ (-6.43 0.17), and an effective function in the pH range from 3 to 8. The resulting response time was quite good, 6.7 sec, with a change of 27.5 mV for a decade. The Pb-ISE sensor also showed validation results equivalent to AAS standard method, where the corresponding data with real samples produced values of 9.3 1.9 and 9.2 2.0 ppm and 275.5 10.3 and 277.7 4.0 g/g, for CREW and CRMS, respectively.
Sign in to start a discussion.
More Papers Like This
A high-performance fluorescent hybrid material for fluorometric detection and removal of toxic Pb(ii) ions from aqueous media: performance and challenges
Researchers developed a new fluorescent hybrid material capable of detecting and removing toxic lead ions from water. The sensor showed high sensitivity and selectivity for lead, with a low detection limit and the ability to work in real water samples. The study demonstrates a promising dual-function tool that could help both monitor and clean up heavy metal contamination in water sources.
Insights Into the Adsorption Behavior of Polyethylene Microplastics Towards Lead(II) Ions
Researchers investigated the adsorption behavior of lead(II) ions onto polyethylene microplastics in freshwater environments by systematically varying initial Pb(II) concentration, pH, and residence time, using scanning electron microscopy and other characterization methods to elucidate the interaction dynamics and sorption mechanisms between this common metal contaminant and microplastic surfaces.
Exploring the Adsorption of Pb on Microalgae-Derived Biochar: A Versatile Material for Environmental Remediation and Electroanalytical Applications
Researchers developed biochar from the marine microalga Nannochloropsis sp. at 350 degrees C and found it outperformed nutshell-derived biochar for adsorbing lead (II) ions in aqueous solution under all tested conditions including varying pH, ionic strength, and dissolved organic matter. The microalgae-derived biochar also improved voltammetric lead detection sensitivity by twofold when applied to screen-printed electrodes.
A bifunctional robust metal sulfide with highly selective capture of Pb2+ ions and luminescence sensing ability for heavy metals in aqueous media
Researchers developed a 3D metal sulfide ion exchanger capable of selectively removing lead ions from water with high efficiency. While focused on heavy metal removal, similar ion exchange materials could potentially be combined with microplastic removal in water treatment systems, since plastics often carry sorbed heavy metals.
Label-free impedimetric analysis of microplastics dispersed in aqueous media polluted by Pb2+ ions
Researchers developed a simple electrochemical method to distinguish between clean and lead-contaminated microplastics in water without needing complex laboratory equipment. The technique uses impedance measurements to rapidly detect whether microplastics carry adsorbed heavy metal pollutants. The approach could be useful for quick field assessments of how contaminated microplastics are in environmental water samples.