0
Article Tier 2 Detection Methods Environmental Sources Human Health Effects Policy & Risk Remediation Sign in to save

Identification and Mitigation of Deposited Indoor Air Microplastics in an Office Environment in Kuala Lumpur

E3S Web of Conferences 2024 1 citation

AI summary Read the abstract

Air purifier units were tested for their effectiveness in reducing microplastic concentrations in office environments at a Malaysian university. The study characterized indoor microplastic contamination sources and demonstrated that air purification can meaningfully reduce settled and airborne microplastic levels in office settings.

Body Systems

Microplastic (MP) contamination in indoor environments has become a growing concern due to its potential health risks and environmental implications. Since humans spend a significant portion of their lives indoors, exposure to MPs through various pathways, including settled dust, air, water, and food, is a substantial concern. Ventilation, air conditioning, and filtration systems play a crucial role in improving indoor air quality. This study investigated the effectiveness of Air Purifier Units (APUs) in reducing MP concentrations in office environments within a Malaysian university. The efficiency of APUs can vary depending on factors such as purifier type, filtration method, airflow rate, and room size. The results demonstrated a 35% average reduction in MP counts when APUs were operational, regardless of whether air vents were open or closed. Specifically, with air vents open, MP counts decreased from 1273.8 to 825.5 when the APU was on. Similarly, with air vents closed, counts dropped from 1272.4 to 831.5. These findings were further validated through statistical analysis using the Shapiro-Wilk test for normality and the Kruskal-Wallis test, Wilcoxon Signed-Rank Test, and Dunn’s test for group comparisons. The study’s findings highlight the significant impact of APUs in mitigating airborne MP exposure, contributing to improved indoor air quality and reducing potential health risks associated with MP inhalation. These results provide valuable insights for building managers, policymakers, and individuals seeking to create healthier indoor environments.

More Papers Like This

Article Tier 2

Airborne Microplastics in Indoor and Outdoor Environments at Universiti Teknologi Malaysia, Kuala Lumpur Campus

AI summary Read the abstract

Researchers collected airborne microplastic samples from indoor and outdoor environments at a Malaysian university campus, finding microplastics present in all locations with higher concentrations indoors and fiber morphologies predominating, suggesting occupants are continually exposed via inhalation.

Article Tier 2

Assessing the concentration, distribution and characteristics of suspended microplastics in the Malaysian indoor environment

AI summary Read the abstract

Researchers measured airborne microplastic levels inside offices, classrooms, apartments, and homes across Malaysia over six weeks. Microplastics were found in every indoor environment tested, with fibers being the most common type, and people in homes were estimated to inhale more microplastics daily than those in offices or classrooms. The findings highlight that indoor air is a significant and often overlooked source of microplastic exposure for people.

Article Tier 2

Assessing Microplastic Distribution in Indoor Environments: A Case Study of a University Facility in Kuala Lumpur

AI summary Read the abstract

Microplastics were detected in the indoor air and settled dust of a Malaysian university building at concentrations averaging 156 particles per cubic metre in offices and 104 in classrooms, with estimated daily adult intakes of over 150 microplastic particles per kilogram of body weight per day. These findings confirm that indoor environments — where people spend the majority of their time — are a significant and often overlooked route of human microplastic inhalation and ingestion.

Article Tier 2

Determination of microplastics in university interior environments

AI summary Read the abstract

This study measured airborne microplastic concentrations in indoor environments at a university, finding particles in air samples from multiple indoor settings. Results contribute to evidence that indoor air represents a significant daily source of microplastic inhalation exposure, particularly given the time people spend in closed indoor environments.

Article Tier 2

Analysis of suspended atmospheric microplastics size at different elevation in Universiti Teknologi Malaysia, Kuala Lumpur

AI summary Read the abstract

Researchers sampled atmospheric microplastics at two different elevations on a Malaysian university campus, finding microplastic contamination in suspended air particles even in urban academic settings, with characteristics varying by elevation.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper