0
Article Tier 2 Detection Methods Environmental Sources Human Health Effects Marine & Wildlife Nanoplastics Remediation Sign in to save

Quantitative Determination of Poly(methyl Methacrylate) Micro/Nanoplastics by Cooling-Assisted Solid-Phase Microextraction Coupled to Gas Chromatography–Mass Spectrometry: Theoretical and Experimental Insights

Analytical Chemistry 2024 21 citations

AI summary Read the abstract

Scientists developed a new, simplified method to detect and measure tiny plastic particles (micro and nanoplastics) made of PMMA (commonly known as acrylic or plexiglass) in water and soil. The technique uses a single step that both breaks down the plastic and captures the signature chemicals for analysis, achieving detection limits as low as 0.01 micrograms per liter. Better measurement tools like this are essential for understanding how much microplastic contamination exists in our environment and assessing its potential impact on health.

Polymers

Determinations of micro/nanoplastics (MNPs) in environmental samples are essential to assess the extent of their presence in the environment and their potential impact on ecosystems and human health. With the aim to provide a sensitive method with simplified pretreatment steps, cooling-assisted solid-phase microextraction (CA-SPME) coupled to gas chromatography-mass spectrometry (GC-MS) is proposed as a new approach to quantify mass concentrations of MNPs in water and soil samples. The herein proposed CA-SPME method offers the unique advantage of integrating the thermal decomposition of MNPs and enrichment of signature compounds into one step. Poly(methyl methacrylate) (PMMA) was used as a model substance to verify the method performance in this work. Theoretical insights demonstrated that pyrolysis is the rate-determining step during the extraction process and that PMMA is effectively decomposed at 350 °C with an estimated incubation time of 13 min. Eight compounds were identified in the pyrolysis products by CA-SPME-GC-MS with the use of a DVB/CAR/PDMS coating, wherein methyl methacrylate was considered as the best indicator and dimethyl 2-methylenesuccinate was selected as the confirmation compound. Under the optimized conditions, the proposed method exhibited wide linearity (0.5-2000 μg for water and 5-1000 μg for soil) and high sensitivity, with limits of detection of 0.014 and 0.28 μg for water and soil, respectively. Finally, the proposed method was successfully applied for determinations of PMMA MNPs in real water and soil samples with satisfactory recoveries attained. The method only required the employment of a filter membrane for water analysis, while soil samples were analyzed directly without any pretreatment. The solvent-free approach, straightforward operation, and high sensitivity of the proposed method show great potential for the analysis of MNPs in different environmental samples.

More Papers Like This

Article Tier 2

Monitoring Poly(methyl methacrylate) and Polyvinyl Dichloride Micro/Nanoplastics in Water by Direct Solid-Phase Microextraction Coupled to Gas Chromatography–Mass Spectrometry

AI summary Read the abstract

Researchers developed a novel method for detecting and quantifying micro- and nanoplastics in water using solid-phase microextraction coupled with gas chromatography-mass spectrometry. The technique successfully identified poly(methyl methacrylate) and polyvinyl dichloride particles at low concentrations without requiring extensive sample preparation. The study offers a simpler, more sustainable, and more sensitive approach for monitoring plastic particle contamination in aqueous environments.

Article Tier 2

Simply Applicable Method for Microplastics Determination in Environmental Samples

AI summary Read the abstract

Researchers developed a simplified headspace solid-phase microextraction followed by GC-MS method for detecting and identifying microplastics in environmental soil and water samples, offering a more accessible alternative to pyrolysis-GC-MS for routine environmental monitoring.

Article Tier 2

The Challenge of Matrix Interference in Quantitative Analysis of PM2.5 Microplastics Using Pyrolysis–Gas Chromatography-Mass Spectrometry

AI summary Read the abstract

Scientists found that a common method for detecting tiny plastic particles in air pollution can give wrong results because of chemical interference from other pollutants like salts. They developed a simple water-rinsing technique that fixes this problem and gives more accurate measurements. This matters because we need reliable ways to measure how much plastic pollution people are breathing in, which could affect our health.

Article Tier 2

Identification and Quantification of Nanoplastics in Surface Water and Groundwater by Pyrolysis Gas Chromatography–Mass Spectrometry

AI summary Read the abstract

Researchers developed a method combining ultrafiltration and pyrolysis gas chromatography-mass spectrometry to identify and quantify nanoplastics in surface water and groundwater. The study successfully detected six types of plastic polymers at the nanoscale in environmental water samples, providing much-needed quantitative data on nanoplastic pollution in real-world water sources.

Article Tier 2

Cloud-Point Extraction Combined with Thermal Degradation for Nanoplastic Analysis Using Pyrolysis Gas Chromatography–Mass Spectrometry

AI summary Read the abstract

Researchers developed a cloud-point extraction method combined with pyrolysis GC-MS to detect and quantify nanoplastics in aqueous samples, achieving detection of particles smaller than those typically measurable with conventional microplastic methods. The technique addresses a critical analytical gap in understanding nanoplastic contamination in water environments.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper