0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Policy & Risk Sign in to save

Detection of microplastics via a confocal-microscope spatial-heterodyne Raman spectrometer with echelle gratings

Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy 2024 10 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Fuguan Li, Fuguan Li, Nannan Song, Xiaotian Li, Jirigalantu Jirigalantu, Xiaotao Mi, Ci Sun, Ci Sun, Yuqi Sun, Shulong Feng, Geng Wang, Jun Qiu, Bayanheshig Bayanheshig

Summary

Researchers built a confocal microscope combined with an echelle-grating spatial-heterodyne Raman spectrometer for detecting microplastics with high sensitivity and resolution. The system achieved spectral resolution approaching 0.67 wavenumbers per centimeter and successfully identified different plastic polymer types. The study demonstrates an efficient and reliable optical detection method that could improve real-time monitoring of microplastic contamination.

Microplastic pollution has become a global environmental problem that cannot be ignored. Raman spectroscopy has been widely used for microplastics detection because it can be performed in real-time and is non-destructive. Conventional detection techniques have had weak signals and low signal-to-noise ratios (SNR). Here, an efficient and reliable detection method is demonstrated. Specifically, a confocal microscope combined with an echelle-grating spatial-heterodyne Raman spectrometer (CM-ESHRS) was constructed. The confocal microscopy and the characteristics of the echelle grating enabled high optical throughput, high SNR, high spectral resolution, and a wide spectral detection band. After spectral calibration, the resolution approached 0.67 cm-1, moreover, the spectral detection range for a single order was 1372.16 cm-1. We detected and analyzed nineteen kinds of microplastics, such as polyamide, polypropylene, and polymethylmethacrylate, and the main vibrational spectral bands were categorized. Compared with commercial dispersive spectrometers, CM-ESHRS has a higher optical throughput. In addition, we examined microplastics with various particle sizes, microplastics mixed in flour, and microplastic particles of different materials under mixed conditions, all of which yielded complete spectral information. Overall, CM-ESHRS exhibits good potential applications for the detection of microplastics.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Detection of microplastics via a frequency-shifted excitation confocal micro-differential, spatial heterodyne, Raman spectrometer with echelle-mirror structure

Researchers developed a microplastic detection system integrating frequency-shifted excitation differential spectroscopy, confocal microscopy, and spatial heterodyne Raman spectroscopy with an echelle-mirror structure, enabling more sensitive identification of microplastic particles.

Article Tier 2

Design of a confocal micro-Raman spectroscopy system and research on microplastics detection

Researchers built a custom confocal micro-Raman spectroscopy system designed to detect microplastics more cost-effectively than commercial instruments. The improved signal quality enables more accurate identification of plastic polymer types in environmental samples.

Article Tier 2

Detection of microplastic samples based on spatial heterodyne microscopic differential Raman spectroscopy

Researchers built a new optical instrument — spatial heterodyne microscopic differential Raman spectroscopy — specifically designed to identify microplastics more reliably than conventional detectors. The system achieved better signal-to-noise ratios for four common plastic types (PS, PC, PP, HDPE) and suppressed fluorescence interference, all without an expensive microscope. Better detection tools like this are essential for accurately measuring microplastic contamination in environmental samples.

Article Tier 2

Detection of microplastics based on splicing grating spatial heterodyne Raman spectroscopy

Researchers developed a new Raman spectroscopy technique using spliced gratings to detect and identify microplastics with improved accuracy and spectral range. The system achieved a spectral resolution of about 5.6 inverse centimeters and successfully identified common microplastic types including polyethylene, polypropylene, and polystyrene. This technology could make field-based microplastic monitoring faster and more reliable than current detection methods.

Article Tier 2

High-resolution, broad-spectral-range Raman measurement using a spatial heterodyne spectrometer with separate filters and multi-gratings

Researchers developed a spatial heterodyne Raman spectrometer with separate filters and multiple gratings that achieves high spectral resolution over a broad range in a single measurement, and demonstrated it can identify microplastics even in the presence of fluorescence interference. Better analytical tools like this are critical for accurately characterizing the types and quantities of microplastics in environmental samples.

Share this paper