Removal of toxic metals from sewage sludge by EDTA and hydrodynamic cavitation and use of the sludge as fertilizer
Summary
This study tested EDTA chelation combined with hydrodynamic cavitation to remove toxic metals from sewage sludge, achieving high removal efficiencies for lead, cadmium, and zinc, enabling safer use of the treated sludge as agricultural fertilizer.
Sewage sludge (SS) is rich in plant nutrients, including P, N, and organic C, but often contains toxic metals (TMs), which hinders its potential use in agriculture. The efficiency of removal of TMs by washing with ethylenediamine tetraacetate (EDTA), in combination with hydrodynamic cavitation (HC) and the usability of washed sewage sludge as fertilizer were investigated. The environmental risk was assessed. During 8 wash batches an average 35, 68, 47 and 45 % of Pb, Zn, Cd and Cu, respectively, as well as 22 and 5 % Mn and Fe were removed from the SS. The process solutions and EDTA were recycled at a pH gradient of 12.5-2, which was achieved by adding quicklime (CaO) and then acidification by H2SO4, so that no wastewater was produced, only solid waste (ReSoil® method). The quality of the recycled process solutions (they remained unsaturated with salts) and the efficiency of the washing process were maintained across all batches. On average, 46 % of the EDTA was lost during the process and was replenished. The initial leachability of EDTA-mobilized Pb, Zn, Cu, Cr and Fe remaining in the washed SS increased 6-, 17-, 3-, 11- and 11-fold, respectively, but not to hazardous levels except for Zn. After washing, P and K remained in the SS, plant-available P increased 3.3-fold, while total N and C were reduced by 20.28 and 2.44 %, respectively. Washed SS was used as fertilizer in the pot experiment. The yield of Brassica juncea did not improve, the uptake of TMs by the plants and the leaching of TMs from the soil were minimal. Our study highlighted the drawbacks and potential feasibility of the new SS washing method.
Sign in to start a discussion.
More Papers Like This
Removal of toxic metals from sewage sludge by EDTA in a closed-loop washing process
Researchers tested a closed-loop EDTA washing process for removing toxic metals from sewage sludge, achieving average removal rates of 59% for zinc and 60% for copper across 10 consecutive washing batches with no wastewater generated, while demonstrating that the process preserves sludge nutrient content within acceptable limits for potential land application.
Removal of Toxic Metals from Sewage Sludge by Acid Hydrolysis Coupled with EDTA Washing in a Closed-Loop Process
Researchers evaluated acid hydrolysis coupled with EDTA washing in a closed-loop ReSoil process for removing toxic metals from sewage sludge, achieving average removals of 78% Pb, 76% Zn, 17% Cr, and 1% Cu across five consecutive batches, with EDTA and process solutions recycled at a pH gradient of 12.5-2 to eliminate wastewater generation.
Integral analysis of hydrodynamic cavitation effects on waste activated sludge characteristics, potentially toxic metals, microorganisms and identification of microplastics
Researchers investigated hydrodynamic cavitation as a pretreatment for waste activated sludge, analyzing its effects on sludge characteristics, toxic metals, microorganisms, and identifying microplastics present in the sludge to improve anaerobic digestion efficiency.
Sustainable Approaches for Wastewater Treatment: An Analysis of Sludge-Based Materials for Heavy Metal Removal from Wastewater by Adsorption
This review synthesized findings on sludge-based materials as adsorbents for heavy metal removal from wastewater, providing a comprehensive foundation for understanding how different sludge types, activation treatments, and operating conditions affect metal removal performance.
Integral analysis of hydrodynamic cavitation effects on waste activated sludge characteristics, potentially toxic metals, microorganisms and identification of microplastics
Researchers tested hydrodynamic cavitation — a process using high-speed water flow to create pressure changes — as a pretreatment to improve sewage sludge digestion and measured its effects on microplastics in the sludge. The process reduced some sludge properties that limit biogas production, but its effect on microplastic fragmentation was also assessed. The study is relevant to understanding how wastewater treatment alters microplastic size and abundance in sludge spread on farmland.