0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Human Health Effects Sign in to save

Into the Nanograms─Sensitive Detection of Microplastics in Passively Sampled Indoor Air Using F-Splitless Pyrolysis Gas Chromatography Mass Spectrometry

ACS ES&T Air 2024 8 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 55 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
William Pipkin, Masumi Sato, Shogo Kumagai, Chuichi Watanabe, Chuichi Watanabe, Atsushi Watanabe, Norio Teramae, Toshiaki Yoshioka

Summary

Researchers developed a highly sensitive method for detecting airborne microplastics in indoor air at the nanogram level using advanced pyrolysis gas chromatography. The study suggests this technique can rapidly identify and quantify microplastics on air sampling filters with minimal preparation, making it easier for scientists to measure the scale of indoor microplastic exposure.

The presence in the atmosphere of airborne plastic, referred to as microplastic, results from the large quantities of plastic waste produced by humans. Microplastics can have an impact on human health. In this study, we investigated the analysis of indoor airborne microplastics by pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS). Py-GC/MS can be used to identify and quantify various types of microplastics. Indoor air was passively sampled using quartz fiber filters. In one instance, active sampling was used for comparative purposes. Sample preparation was limited and consisted only of cryomilling the quartz filters used for sampling to ensure homogeneity. F-Splitless pyrolysis, which is accomplished by forcibly redirecting flows, was used to transfer all the pyrolyzates of the microplastics to the GC/MS system. The results demonstrate that F-Splitless Py-GC/MS can be used to identify and quantify microplastics at the nanogram level. This method enables the rapid characterization and quantitation of microplastics in particulate matter (PM) air filters with minimal sample preparation, direct measurement of the sampling media, and nanogram-level sensitivity, thereby, allowing researchers to ascertain the magnitude of the microplastic threat in environmental air.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Size-resolved identification and quantification of micro/nano-plastics in indoor air using pyrolysis gas chromatography-ion mobility mass spectrometry

A novel pyrolysis gas chromatographic cyclic ion mobility mass spectrometer method was developed to identify and quantify micro- and nanoplastics smaller than 1 micrometer in indoor air, finding four common plastic types in tested samples.

Article Tier 2

Size-Resolved Identification and Quantification of Micro/Nanoplastics in Indoor Air Using Pyrolysis Gas Chromatography–Ion Mobility Mass Spectrometry

Scientists developed a new method to measure micro and nanoplastics in indoor air down to 56 nanometers in size, using advanced mass spectrometry techniques. They found significant concentrations of plastic particles in both a laboratory and a private home, with polystyrene being the most common type, and also detected flame retardant chemicals associated with plastic furniture foam. This study provides some of the first evidence that people are breathing in substantial amounts of nanoscale plastic particles indoors, where most people spend the majority of their time.

Article Tier 2

Pyr-GC-Orbitrap-MS method for the target/untargeted analysis of microplastics in air

Researchers developed a pyrolysis-gas chromatography method coupled with Orbitrap mass spectrometry for detecting microplastics in air samples. The technique was optimized for ten common plastic polymers and achieved detection limits in the low microgram range. The study demonstrates that this analytical approach can identify both known and unknown plastic polymers in airborne particulate matter.

Article Tier 2

A Novel Strategy to Directly Quantify Polyethylene Microplastics in PM2.5 Based on Pyrolysis-Gas Chromatography–Tandem Mass Spectrometry

Researchers developed a new method using pyrolysis gas chromatography-tandem mass spectrometry to directly measure polyethylene microplastics in fine airborne particulate matter (PM2.5). This technique overcomes limitations of visual and spectroscopic methods that struggle to detect very small plastic particles in air samples. The study provides one of the first tools for accurately quantifying microplastics in PM2.5, helping researchers better understand the extent of airborne plastic pollution.

Article Tier 2

Mass spectrometry as a powerful analytical tool for the characterization of indoor airborne microplastics and nanoplastics

This review covers recent mass spectrometry-based analytical methods for determining the size, chemical identity, and quantity of microplastics and nanoplastics in indoor air and dust. It highlights how advances in single-particle mass spectrometry are enabling more sensitive detection of nano-sized plastic fragments in indoor environments.

Share this paper