0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Human Health Effects Remediation Sign in to save

Treatment of electroplating wastewater using electrocoagulation and integrated membrane

Water Science & Technology 2024 14 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 60 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Le Zhang, Linxin Qin, Lanting Ma, Zhe Shen, Yabin Jin, Si Chen

Summary

This study developed an electrocoagulation and membrane filtration system that removes over 99% of heavy metals from industrial wastewater. While not directly about microplastics, the technology is relevant because microplastics in water often carry heavy metals that can leach into drinking water. Improved industrial wastewater treatment reduces the overall toxic burden in water systems that people depend on.

Study Type Environmental

Electroplating wastewater contains heavy metal ions and organic matter. These contaminants not only endanger the environment but also pose risks to human health. Despite the development of various treatment processes such as chemical precipitation MBR, electrocoagulation (EC) ceramic membrane (CM), coagulation ultrafiltration (UF) reverse osmosis (RO), and CM RO. These methods are only effective for low concentrations of heavy metals and struggle with high concentrations. To address the challenge of treating electroplating wastewater with high heavy metal content, this study focuses on the wastewater from Dongfang Aviation Machinery Processing Plant. It introduces an EC and integrated membrane (IM) treatment process for electroplating wastewater. The IM comprises microfiltration (MF) membrane, nanofiltration (NF) membrane, and RO membrane. Results indicated that under specific conditions, such as a pH of 8, current density of 5 A/dm2, electrode plate spacing of 2 cm, 35 min of electrolysis time, and influent pH of 10 for the IM, removal rates of Zn2+, Cu2+, Ni2+, and TCr in the wastewater exceeded 99%. The removal rates of chemical oxygen demand (COD), suspended solids (SS), total phosphorus (TP), total nitrogen (TN), and petroleum in wastewater exceed 97%. Following a continuous cleaning process, the membrane flux can consistently recover to over 94.3%.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Electrocoagulation as a Possible Treatment for Wastewater Contaminated with Microplastics - A Review

This review examined electrocoagulation and hybrid membrane technologies as innovative approaches for removing microplastics from wastewater, noting that MPs are omnipresent pollutants capable of biomagnification. The review covered the effectiveness of electrochemical processes, advanced oxidation, and membrane filtration systems including their combination for enhanced microplastic removal.

Review Tier 2

Electrocoagulation in Wastewater Treatment: A Comprehensive Review of Heavy Metal and Pollutant Removal

This comprehensive review evaluates electrocoagulation as a wastewater treatment method for removing heavy metals and other pollutants, including microplastics. Researchers found that electrocoagulation is a versatile and effective technique compared to conventional methods like membrane filtration or chemical coagulation. The study highlights its advantages in terms of environmental compatibility and cost-effectiveness, while noting that optimization of operating parameters is still needed for different wastewater types.

Article Tier 2

Removal of microplastics from wastewater through electrocoagulation-electroflotation and membrane filtration processes

Researchers investigated electrocoagulation-electroflotation and membrane filtration for removing microplastics from wastewater, finding that combining these processes effectively recovers microplastic particles from treatment plant effluent.

Article Tier 2

Electrochemical remediation of microplastics: Progress and prospects in water treatment

This review examines electrochemical methods for removing microplastics from water, including electrocoagulation, electro-oxidation, and the electro-Fenton process. Evidence indicates that electro-oxidation can achieve removal rates as high as 99 percent under optimized conditions. The study highlights these techniques as promising alternatives for water treatment but calls for further research to scale them up for real-world applications.

Article Tier 2

Title Perniciousness of microplastics in the ocean and electrocoagulation in microplastic removal in effluent treatment process

This study reviewed the environmental harms of microplastics in the ocean and assessed electrocoagulation as a removal technology for wastewater treatment. Electrocoagulation showed promise as an effective and scalable method for removing microplastics from wastewater before ocean discharge.

Share this paper