Microplastics and dye removal from textile wastewater using MIL-53 (Fe) metal-organic framework-based ultrafiltration membranes
Summary
Researchers developed an advanced ultrafiltration membrane using a metal-organic framework material to simultaneously remove microplastics and dyes from textile wastewater. The modified membrane showed improved pollutant rejection rates and better resistance to fouling compared to conventional membranes. The study demonstrates a promising approach for tackling multiple contaminants in one of the most polluting industrial wastewater streams.
Microplastics (MPs) and other organic matters in textile wastewater have posed a formidable challenge for treatment processes, particularly in the primary stages such as ultrafiltration (UF). UF plays a crucial role in preventing the entry of pollutants into subsequent treatment steps. However, the performance efficiency of UF membranes is compromised by the potential fouling of membrane pores by MPs, dyes and other organic pollutants such as bovine serum albumin (BSA). This study focuses on enhancing UF membrane performance, specifically its antifouling properties, through the development of high-performance membranes using MIL-53(Fe) metal-organic framework (MOF) particles (noted as MIL-53 here). Various concentrations of the MIL-53 (0.05, 0.1, 0.2, and 0.5 wt%) were integrated into the membrane structure through phase inversion process. Streaming zeta potential results confirmed the negatively charged surface of the membranes and their high hydrophilicity was validated through contact angle analysis. FTIR, SEM, EDS, and XRD confirmed the presence of MIL-53 particles on the surface of membranes. The developed membranes were tested for 24 h to assess their antifouling properties, with a subsequent 30-min hydraulic flush to measure their flux recovery ratios. Methylene Blue (MB) dye was used as a cationic dye present in textile wastewater to evaluate the efficiency of the developed membranes in dye removal and the synergistic effects of dye rejection in the presence of organic matters (i.e., MPs and BSA). Since previous studies have not fully addressed the combination of dyes and organic matter, this study thoroughly investigated the effect of particle-type foulants (MPs) and their interactions with dye (MB), as well as water soluble protein-type foulants (BSA) and their interaction with MB. The results indicated that the developed membranes exhibited higher MB rejection when the dye was present with either MP or BSA, along with improved antifouling properties. The optimised UF membrane integrated with 0.1 wt% MIL-53 demonstrated nearly 96% BSA rejection and around 86% MB rejection in the mixed foulant case (BSA-MB). The modified membrane exhibited a substantial increase in water flux from 176 L m.h to 327 L m.h. The findings of this research show the potential of iron-based MOFs in improving the performance of UF membranes and provide a platform for future studies on significant areas such as long-term stability studies and testing with other pollutants found in textile wastewater.
Sign in to start a discussion.
More Papers Like This
Performance of MOF-containing active layer and HOF-based support layer of ultrafiltration membrane for nanoplastics removal from secondary effluent
Researchers built a novel ultrafiltration membrane using two advanced porous framework materials to filter nanoplastics out of real wastewater treatment plant effluent, successfully identifying and removing poly(methyl methacrylate), polyethylene, and polystyrene nanoparticles. The work addresses a critical gap because conventional wastewater treatment does not reliably remove nanoplastics before treated water is discharged.
Evaluating the performance of the metal organic framework-based ultrafiltration membrane for nanoplastics removal
Researchers created an advanced membrane filter using metal-organic framework nanoparticles that removed over 99% of nanoplastics from water while maintaining high water flow rates. The membrane resisted fouling and worked reliably across multiple cycles and different water conditions. This type of technology could improve wastewater treatment plants' ability to prevent nanoplastics from reaching drinking water supplies.
Toward Scalability: Fe‐MOF‐Based Ultrafiltration Membrane for Effective Microplastics Removal from Drinking Water at Point‐of‐Use
Researchers developed a metal-organic framework composite membrane for removing microplastics from drinking water at point-of-use. By integrating an iron-based MOF onto a commercial ultrafiltration membrane, they achieved enhanced removal of PET microplastics while maintaining water flow suitable for practical use. The study demonstrates a scalable approach to reducing microplastic exposure from bottled and tap drinking water.
Reuse of Water in Laundry Applications with Micro- and Ultrafiltration Ceramic Membrane
Microfiltration and ultrafiltration ceramic membranes were compared for the treatment of laundry wastewater containing microfibers, with both membranes achieving high microfiber removal while the ultrafiltration membrane provided better water quality for reuse. The study supports ceramic membrane filtration as an effective approach to capturing textile microplastics at the point of washing.
Fabrication of dual-charged MOF-based ultrafiltration membrane to remove charged nanoplastics from wastewater
Researchers developed a new type of water filter membrane that can remove over 99% of nanoplastics from wastewater while maintaining high water flow. The membrane uses metal-organic framework nanoparticles that repel plastic particles through electrical charges and physical filtering. This technology could help prevent nanoplastics, which are too small for conventional filters, from reaching drinking water sources.