0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Human Health Effects Sign in to save

Screening of municipal effluents with the peroxidase toxicity assay

Discover Water 2024 2 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
François Gagné, C. André, Shirley-Ann Smyth

Summary

Researchers used a quick enzyme-based test called the peroxidase assay to screen seven types of municipal wastewater treatment processes, finding that 60% of treated effluents released compounds toxic to DNA into the environment, including nanoplastics. The study highlights gaps in conventional wastewater treatment and the ongoing risk of releasing harmful contaminants into waterways.

Abstract The peroxidase (Per) reaction is a quick and inexpensive biosensor for the screening of environmental contaminants and wastewaters. The purpose of this study was to screen various municipal wastewaters before and after 7 different types of treatment processes using this sensor to identify potential sites under stress by urban pollution. The following wastewater samples before (influent) and after the commonly applied treatments (effluent) were tested using the Per activity test: advanced biofiltration, biofiltration, aerated lagoons, secondary aeration sludge, trickling filter, secondary membrane filtration, and primary. The influents and effluents were collected for 3 days and concentrated to 500 X on a reverse-phase (C18) extraction cartridge. The ethanol extracts were examined for dissolved organic carbon, plastic-like materials, polyaromatic hydrocarbons and polystyrene nanoplastics. The samples were then tested using the Per reaction alone and in the presence of DNA to detect DNA binding agents. The results show that population size tended to increase Per activity and 60% of the effluents decreased Per activity leading to H 2 O 2 persistence and toxicity. More advanced treatments (biofiltration, membrane biofiltration, secondary aeration) produced stronger changes from the corresponding untreated influents corroborating their performance in reducing toxicity. The addition of DNA during the Per reaction revealed that population size had no influence and that 60% of treated effluents restored Per activity suggesting release of genotoxic compounds in the aquatic environment from treated wastewaters. The toxic implications of the continuous release of wastewaters in aquatic ecosystems are discussed in the light of emerging contaminants such as nanoplastics.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

The peroxidase toxicity assay for the rapid evaluation of municipal effluent quality

Researchers validated a rapid enzyme-based test for evaluating the toxicity of municipal wastewater effluents and found it could detect harmful effects from a range of pollutants including microplastics, pharmaceuticals, and metals. The test showed that microplastics in wastewater interfered with enzyme activity in a dose-dependent manner. The study offers a fast and cost-effective screening tool that could help water treatment facilities monitor effluent quality more frequently.

Article Tier 2

Screening of municipal effluents with the peroxidase toxicity assay

This study screened municipal effluents using a peroxidase toxicity assay, quantifying the combined oxidative stress potential of wastewater discharges and evaluating whether treatment reduces this form of biological toxicity.

Article Tier 2

Microplastic pollution is widely detected in US municipal wastewater treatment plant effluent

Researchers conducted a wide survey of US municipal wastewater treatment plants and found microplastics widely present in effluent, confirming that conventional treatment does not fully remove microplastics and that treatment plants are ongoing sources of environmental contamination.

Article Tier 2

Effectiveness of conventional municipal wastewater treatment plants in microplastics removal: Insights from multiple analytical techniques

Researchers evaluated the effectiveness of conventional municipal wastewater treatment plants in removing microplastics across multiple treatment stages, finding removal efficiencies of 70–90% but documenting that billions of particles still pass through in final effluent daily.

Article Tier 2

Micro (nano) plastics in wastewater: A critical review on toxicity risk assessment, behaviour, environmental impact and challenges

Researchers reviewed the sources, detection methods, toxicity, environmental fate, and wastewater treatment options for micro- and nanoplastics, finding that nanoplastics are especially persistent and toxic due to their large surface area and ability to carry co-pollutants, and identifying key research gaps in quantification, degradation mechanisms, and sensor development.

Share this paper