We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Design optimisation of rare earth metal doped polymer optical planar waveguide sensor for microplastics detection in water
AI summary Read the abstract
Researchers simulated a rare-earth-metal-doped polymer optical waveguide sensor using COMSOL Multiphysics, finding that reducing cladding thickness to zero maximized sensitivity by a factor of 10 million compared to a 5 μm cladding design, enabling detection of microplastics in water through refractive index shifts. Advances in miniaturized, highly sensitive optical sensors are critical for real-time, field-deployable monitoring of microplastic contamination in drinking water and aquatic ecosystems.
In recent times, the issue of microplastic pollution has garnered worldwide attention as it poses threat to both the environment and wildlife, including human health. This work demonstrated a simulation of a rare earth metal-doped polymer optical planar waveguide sensor with a circular core design to realise future sensing applications of detecting microplastics in water by utilising the Wave Optics Module in COMSOL Multiphysics® software. The sensor design optimisation was performed by varying the cladding thickness from 0 to 5 μm at a fixed 10 µm circular core diameter. The simulation involved changing the refractive index (RI) of the analyte, which varied from 1.480 to 1.500 refractive index units (RIUs) with respect to the RI of microplastics, to assess the optimum waveguide design for sensitivity performance of the sensor. The results successfully showed that the sensitivity of the waveguide sensor increased with decreasing cladding thickness. The highest sensitivity of 2.75 × 10–4 in dimensionless unit was achieved for 0 µm cladding thickness waveguide sensor design. This sensitivity is 107 higher in magnitude than 5 µm cladding thickness, with an output sensitivity of 8.40 × 10–11 in dimensionless unit. Considerably, incorporating the rare earth metal-doped polymer composite into materials with an optimised waveguide sensor design of 0 µm cladding thickness assures an excellent sensing potential for microplastic detection in water.
More Papers Like This
Sensing of Microplastics Using Advanced Materials: A Comprehensive Review
AI summary Read the abstract
This review surveys advanced materials—including iron oxide and gold nanoparticles, quantum dots, carbon nanotubes, MOFs, conductive polymers, and biopolymers—that enable sensitive detection and removal of microplastics and nanoplastics from environmental matrices. Rapid, reliable sensing technologies are foundational to understanding human and ecological exposure levels and evaluating the effectiveness of remediation strategies.
Optical innovations in microplastic analysis: a critical review of detection strategies
AI summary Read the abstract
Researchers reviewed the current landscape of optical detection methods for microplastics—spanning Raman and FTIR spectroscopy, SERS, FLIM, hyperspectral imaging, and AI-enhanced analysis—highlighting that while handheld and smartphone-based platforms show strong promise for field deployment, the absence of standardized protocols and interference from organic matter remain key barriers to reliable environmental monitoring.
Microplastic Detection Using Dual-Mode Complementary Split-Ring Resonator
AI summary Read the abstract
Researchers developed a microplastic detection sensor using dual-mode complementary split-ring resonators operating at 2.45 and 5.8 GHz ISM bands, achieving concentration measurements of polyethylene in water with errors under 3.51% across 0–800 ppm ranges. Accurate, low-cost sensing technology like this is essential for real-time environmental monitoring of microplastic levels in water systems before they reach drinking water supplies.
Design Optimisation of Optical Planar Waveguide Sensor for Microplastics Detection in Water
AI summary Read the abstract
Researchers simulated an optical planar waveguide sensor design for microplastic detection in water using the Wave Optics Module in COMSOL Multiphysics, optimising cladding thickness (0-5 µm) and evaluating sensor performance across the refractive index range (1.480-1.500 RIU) corresponding to microplastic materials.
Plasmonic Detection of Microplastics and Microorganisms Using a Circular-Nanorod-Coupled MIM Sensor
AI summary Read the abstract
Researchers designed a compact plasmonic sensor based on a silver metal-insulator-metal waveguide coupled to an octagonal cavity embedded with circular nanorods, achieving dual resonance sensitivities of 1,321 and 2,198 nm/RIU that enable optical detection of microplastics and aquatic microorganisms through refractive index shifts.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.