0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Marine & Wildlife Sign in to save

Comparison of Different Vibrational Spectroscopic Probes (ATR-FTIR, O-PTIR, Micro-Raman, and AFM-IR) of Lipids and Other Compounds Found in Environmental Samples: Case Study of Substrate-Deposited Sea Spray Aerosols

ACS Measurement Science Au 2024 11 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 50 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Carolina Molina, Deborah Kim, Lincoln Mehndiratta, Jennie Lee, Jennie Lee, Chamika K. Madawala, Jonathan H. Slade, Alexei V. Tivanski, Vicki H. Grassian

Summary

Researchers compared four different vibrational spectroscopy techniques for analyzing lipids and other compounds in environmental samples, including sea spray aerosols. They found that infrared-based methods could clearly distinguish between different lipid structures, while Raman spectroscopy had difficulty differentiating them. The study demonstrates how combining complementary spectroscopic approaches provides the most comprehensive chemical characterization of environmental particles.

Study Type Environmental

The use of vibrational spectroscopy to probe environmental samples is increasing with the development of new methods, including microspectroscopic probes. In this study, we compare different vibrational methods to interrogate lipids and other compounds found in environmental samples. In particular, we compare the vibrational spectra for different lipids that include fatty acids (protonated and deprotonated forms), fatty alcohols, and fatty esters by utilizing attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy, optical photothermal infrared (O-PTIR) spectroscopy, micro-Raman spectroscopy, and atomic force microscopy infrared (AFM-IR) spectroscopy. We show the utility of infrared methods to clearly delineate the structure of the lipid, i.e., whether it is an acid, alcohol, or ester. In contrast, it is difficult to differentiate these from micro-Raman spectroscopy. Furthermore, in the case of fatty acids, the protonation state can also be determined by infrared methods. In most cases, there is a high correlation between the three different infrared techniques as seen for ATR-FTIR and O-PTIR spectroscopy; however, this is not always true with AFM-IR spectroscopy for samples with low signal-to-noise or in a liquid phase state. Additionally, substrate-deposited aerosols were collected from the Scripps Ocean-Atmosphere Research Simulator (SOARS) and examined with both the O-PTIR and micro-Raman spectroscopy to show how these two vibrational probes together can provide essential chemical insights into environmental samples that are difficult to achieve otherwise.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Analytical tools in advancing microplastics research for identification and quantification across environmental media: from sample to insight

Researchers reviewed the analytical tools most commonly used for identifying and quantifying microplastics, focusing on FTIR and Raman spectroscopy as the two primary methods. The review compared their strengths and limitations and provided guidance for choosing between them based on particle size, sample matrix, and research objectives.

Article Tier 2

Analysis of environmental microplastics by vibrational microspectroscopy: FTIR, Raman or both?

This study reviewed analytical methods for environmental microplastic analysis using vibrational microspectroscopy — comparing FTIR, Raman, and related techniques — and provided guidance on method selection for different sample types and research questions.

Article Tier 2

Optimizing microplastic analysis through comparative FTIR and raman spectroscopy: Addressing challenges in environmental degradation studies

This study optimized microplastic analysis by comparing FTIR and Raman spectroscopy approaches for identifying degraded polymer particles in environmental samples where photooxidation and mechanical fragmentation have altered spectral signatures. A combined spectroscopy approach outperformed either technique alone for accurately identifying degraded microplastics in complex environmental matrices.

Article Tier 2

Critical steps for microplastics characterization from the atmosphere

This systematic review of atmospheric microplastic sampling and characterization methodologies finds that divergent results across studies stem from inconsistent collection and pre-treatment methods, and that the choice of characterization technique (FTIR vs. Raman) should be matched to the MPs' origin and environmental matrix.

Article Tier 2

Refined Analysis of Microplastics: Integrating Infrared and Raman Spectroscopy

This study optimized the use of Fourier Transform Infrared Spectroscopy (FTIR) and Raman spectroscopy for characterizing microplastics in aquatic environments, finding that integrating both techniques improves identification accuracy and physicochemical characterization.

Share this paper