0
Article ? AI-assigned paper type based on the abstract. Classification may not be perfect — flag errors using the feedback button. Tier 2 ? Original research — experimental, observational, or case-control study. Direct primary evidence. Detection Methods Environmental Sources Marine & Wildlife Nanoplastics Policy & Risk Remediation Sign in to save

MicroMetaSense: Coupling Plasmonic Metasurfaces with Fluorescence for Enhanced Detection of Microplastics in Real Samples

ACS Sensors 2024 5 citations ? Citation count from OpenAlex, updated daily. May differ slightly from the publisher's own count. Score: 45 ? 0–100 AI score estimating relevance to the microplastics field. Papers below 30 are filtered from public browse.
Emre Ece, Yusuf Aslan, Nedim Hacıosmanoğlu, Fatih İnci

Summary

The MicroMetaSense platform coupled plasmonic metasurfaces with fluorescence spectroscopy to achieve enhanced detection of microplastics, including particles smaller than 5 µm and nanoplastics below 1 µm. The approach overcame the detection limitations of existing methods, enabling sensitive MP identification in complex environmental and food matrices.

Polymers
Study Type Environmental

Diverse analytical techniques are employed to scrutinize microplastics (MPs)─pervasive at hazardous concentrations across diverse sources ranging from water reservoirs to consumable substances. The limitations inherent in existing methods, such as their diminished detection capacities, render them inadequate for analyzing MPs of diminutive dimensions (microplastics: 1-5 μm; nanoplastics: < 1 μm). Consequently, there is an imperative need to devise methodologies that afford improved sensitivity and lower detection limits for analyzing these pollutants. In this study, we introduce a holistic strategy, i.e., MicroMetaSense, reliant on a metal-enhanced fluorescence (MEF) phenomenon in detecting a myriad size and types of MPs (i.e., poly(methyl methacrylate) (PMMA) and poly(ethylene terephthalate) (PET)) down to 183-205 fg, as well as validated the system with real samples (tap and lake) and artificial ocean samples as a real-world scenario. To obtain precise size distribution in nanometer scale, MPs are initially processed with an ultrafiltration on-a-chip method, and subsequently, the MPs stained with Nile Red dye are subjected to meticulous analysis under a fluorescence microscope, utilizing both a conventional method (glass substrate) and the MicroMetaSense platform. Our approach employs a metasurface to augment fluorescence signals, leveraging the MEF phenomenon, and it demonstrates an enhancement rate of 36.56-fold in detecting MPs compared to the standardized protocols. This low-cost ($2), time-saving (under 30 min), and highly sensitive (183-205 femtogram) strategy presents a promising method for precise size distribution and notable improvements in detection efficacy not only for laboratory samples but also in real environmental samples; hence, signifying a pivotal advancement in conventional methodologies in MP detection.

Sign in to start a discussion.

More Papers Like This

Article Tier 2

Visualizing undyed microplastic particles and fibers with plasmon-enhanced fluorescence

Researchers developed a plasmon-enhanced fluorescence method using gold nanopillar substrates to detect undyed microplastics in water, achieving detection limits as low as 0.35 femtograms — roughly 70 times more sensitive than standard glass-substrate fluorescence microscopy.

Article Tier 2

Plasmonic Nanomaterials for Micro- and Nanoplastics Detection

This review examines plasmonic noble metal nanomaterials (gold, silver, and their alloys) as analytical tools for detecting and quantifying micro- and nanoplastics in environmental samples. Plasmonic materials exploit surface-enhanced Raman scattering and other optical effects to achieve highly sensitive detection of plastic particles.

Article Tier 2

Liquid metasurface for size-independent detection of microplastics

Researchers developed a liquid metasurface sensor that can detect and quantify microplastics regardless of their size, overcoming a major limitation of existing detection methods. The technology uses surface-enhanced Raman scattering on a self-assembled liquid surface to eliminate the size-dependent detection problems that plague conventional solid substrates. This advancement could make it significantly easier to accurately measure microplastic contamination in environmental samples.

Article Tier 2

Identification of microplastics and associated contaminants using ultra high resolution microscopic and spectroscopic techniques

A new procedure combining ultra-high resolution microscopy and spectroscopy was developed to simultaneously characterize micro- and nanoplastics and identify contaminants adsorbed to their surfaces in aquatic samples. The method enables more comprehensive analysis of the complex pollutant mixtures associated with environmental microplastic particles.

Article Tier 2

Advanced microplastic monitoring using Raman spectroscopy with a combination of nanostructure-based substrates

Researchers reviewed advances in Raman spectroscopy and surface-enhanced Raman scattering (SERS) — a technique that amplifies light signals using metallic nanostructures — for detecting micro- and nanoplastics at trace concentrations in environmental samples, highlighting new plasmonic materials, 3D substrates, and microfluidic chip platforms that enable on-site monitoring.

Share this paper