We can't find the internet
Attempting to reconnect
Something went wrong!
Hang in there while we get back on track
Improper Curing of 3D Printed Restorations and Intraoral Degradation: Microplastic Release Health Risks and the Role of Oxygen-Free Polymerisation
AI summary Read the abstract
This review examined how improperly cured 3D-printed dental resin restorations release microplastic particles and leachable monomers in the mouth, identifying incomplete polymerization during fabrication as a key risk factor for intraoral chemical exposure.
Three-dimensional (3D) printing technology has significantly revolutionised the field of restorative dentistry by facilitating the remarkably swift and highly accurate production of customised dental restorations tailored to meet individual patient needs and specifications. Nevertheless, a growing body of evidence increasingly underscores the presence of substantial health risks that are associated with the intraoral degradation of resin-based materials that have not been appropriately cured during the manufacturing process. The phenomenon of incomplete polymerisation—often a consequence of factors such as oxygen inhibition, insufficient exposure to light, or the implementation of suboptimal curing protocols—results in the release of residual monomers and microplastics into the oral cavity, thereby raising serious concerns. These released substances are progressively being recognised as biologically active contaminants that possess the potential to induce a variety of adverse effects, including cytotoxicity, oxidative stress, endocrine disruption, and inflammatory responses that can impact both local tissues within the oral cavity and systemic tissues throughout the body. This comprehensive review aims to synthesise the most current research regarding the chemical and mechanical consequences that arise from inadequate curing processes, the biological pathways that are affected by the ingestion of microplastics and the leaching of monomers, and the broader implications this has for the long-term safety and well-being of patients undergoing such dental procedures. Various strategies that have been proposed—including oxygen-free polymerisation techniques, the use of optimised curing wavelengths (for example, at 385 nm), and the development of modified resin formulations—are discussed as potential means to effectively mitigate these significant health risks associated with dental materials. The findings presented in this review emphasise the pressing necessity for the establishment of standardised protocols and the pursuit of further research endeavours aimed at addressing the concealed health burden that is posed by the degradation of 3D printed dental restorations in the context of clinical dentistry. Ultimately, addressing these challenges will require a collaborative effort among researchers, clinicians, and manufacturers to enhance the safety and efficacy of dental materials in restorative practices.
More Papers Like This
Microscopic Acid‐Induced Degradation and Elemental Release From Thermoformed and 3D ‐Printed Orthodontic Aligners in a Simulated Gastric Environment
AI summary Read the abstract
Researchers evaluated acid-induced degradation and elemental release from thermoformed and 3D-printed orthodontic aligner materials under simulated gastric conditions, finding that both types released microplastic and nanoplastic particles along with chemical additives under acidic exposure, raising concerns about ingestion risks during orthodontic treatment.
Particle and Microplastic Release from Printed Photopolymers: Wear, Weathering, Measurement and Exposure Boundaries
AI summary Read the abstract
3D printed plastic objects, like denture teeth, can shed tiny particles through everyday wear, sanding, and sun exposure. This paper does not measure exact health risks but instead proposes a careful method for scientists to properly measure how much plastic actually breaks off, since sloppy measurements could over or underestimate real world exposure.
Microplastic Release from Dental Materials: Environmental and Biological Implications
AI summary Read the abstract
This review examines how dental materials—composites, adhesives, denture bases, and orthodontic appliances—degrade under mechanical, thermal, enzymatic, and chemical stressors to release microplastics, contributing to both direct patient exposure and environmental contamination.
The Biological Effects of 3D Resins Used in Orthodontics: A Systematic Review
AI summary Read the abstract
This systematic review found that 3D-printed orthodontic resins release bisphenol A and other residual monomers with demonstrated cytotoxic, genotoxic, and estrogenic effects, though few studies have evaluated systemic toxicity in patients. The release of these substances is influenced by printing parameters, post-processing, and material composition. Bisphenol A is also a key chemical of concern in microplastic research, as it leaches from degrading plastic particles and acts as an endocrine disruptor.
What every dentist needs to know about microplastics and dental materials.
AI summary Read the abstract
This review outlined how common dental products — including toothpastes, composites, orthodontic appliances, and floss — contain or generate microplastics through degradation and use, and summarized the health risks from exposure via ingestion, inhalation, and dermal contact.
Research digests by email
When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.