Assessing the efficacy of electrocoagulation process for polypropylene microplastics removal from wastewater: Optimization through TOPSIS approach
Summary
Researchers evaluated electrocoagulation as a method for removing polypropylene microplastics from wastewater, testing different electrode materials and operating conditions. They found that using aluminum electrodes achieved up to 95.5% microplastic removal efficiency with relatively low energy consumption. The study suggests that electrocoagulation is a practical and cost-effective treatment option that could complement existing wastewater treatment processes.
Emerging contaminants, microplastics in particular, pose a substantial risk to human health and the environment. Conventional treatments fail to incorporate focused approaches to eliminate them. This research comprehensively evaluated the effectiveness of electrocoagulation as a techno-economic method for removal of microplastics from water. The research meticulously investigated the effects of various electrode combinations composed of SS (stainless steel) and Al (aluminium) with possible combination as Al-Al, Al-SS, SS-Al and SS. Out of the various combinations considered, it was discovered that the Al-Al coupling demonstrated exceptional efficacy of 95.54% in the elimination of microplastics, with a concurrent reduction in energy consumption. The initial pH value was found to be a crucial parameter, as evidenced by the highest removal efficacy of 92.80% observed at a near neutral alkaline pH of 8. However, in order to determine economic efficacy, it is necessary to consider additional variables including energy consumption, electrode utilisation, and post-treatment conductivity. In order to address the intricacy presented by a multitude of parameters and criteria, it is critical to employ multi-criteria decision-making tools such as Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS), which has demonstrated efficacy in real-world scenarios. The optimal electrolyte concentration, as determined by TOPSIS analysis, is 0.5 g/L. Furthermore, the TOPSIS analysis underscored the superior performance of punched hollow cylindrical electrode. The investigation conducted a thorough assessment of the impact of time period and concluded that a 100-min interval offers the highest efficacy in removing microplastics. At an input concentration of 2 g/L, this enhanced optimized system demonstrated outstanding competence in removing microplastics of three different sizes 45-90 μm, 90-180 μm, and 180-355 μm, with the removal efficiencies of 89.80%, 93.12%, and 94.08%, respectively. The current study introduces a pragmatic and exceptionally efficient approach to tackle the urgent problem of microplastic pollution in aquatic ecosystems.
Sign in to start a discussion.
More Papers Like This
Evaluating the performance of electrocoagulation system in the removal of polystyrene microplastics from water
Researchers tested electrocoagulation, a water treatment method that uses electric current to clump particles together, for removing polystyrene microplastics from water. Using aluminum electrodes at neutral pH, they achieved over 90% removal efficiency. This technology could provide a practical and effective way to remove microplastics from drinking water and wastewater, reducing human exposure to these contaminants.
Electrocoagulation Assessment to Remove Micropolystyrene Particles in Wastewater
Researchers evaluated the use of electrocoagulation for removing micropolystyrene particles from synthetic wastewater, testing variables like electrode material, current density, and particle size. They found that the process was effective at removing microplastics, with aluminum electrodes and higher current densities achieving the best results. The study supports electrocoagulation as a viable treatment technology for reducing microplastic loads in wastewater.
Analysis of the Efficiency of the Electrocoagulation Process in the Removal of Microplastics
Researchers demonstrated that electrocoagulation using aluminum electrodes can remove up to 90% of microplastic glitter particles from water, with efficiency increasing as electrical conductivity and current intensity rise. This low-cost, chemical-free approach shows strong potential as a practical treatment step for removing microplastics from water without adding secondary contaminants.
Assessing the Removal Efficiency of Microplastics from Water Using Electrocoagulation
Researchers in Pakistan tested electrocoagulation as an affordable method for removing microplastics from water, measuring removal efficiency across different electrode materials and operating conditions. The technique achieved high removal rates while meeting sustainable development goals around clean water access, with iron electrodes outperforming aluminum.
Optimizing microplastic treatment in the effluent of biological nutrient removal processes using electrocoagulation: Taguchi experimental design
Researchers optimized an electrocoagulation process using aluminum electrodes to remove microplastics from biological wastewater treatment plant effluent. Using Taguchi experimental design, they identified the most important process variables affecting removal efficiency, including current density and treatment time. The study demonstrates that electrocoagulation can be an effective supplementary treatment step for reducing microplastic discharge from wastewater facilities.