0
Article Tier 2 Sign in to save

Safety and sustainability of potable tap water irrigation in endoscopy in Canada: an interrupted time series study

AI summary Read the abstract

A Canadian hospital study of nearly 30,000 endoscopy procedures compared using sterile water versus regular tap water to rinse during the exams. Switching to tap water, which avoids plastic sterile water bottles, did not increase complications like emergency visits, hospital admissions, or infections within days after the procedure.

Models

Background International guidelines recommend sterile water for endoscopic irrigation despite limited evidence. Single-use plastic sterile water bottles generate substantial costs, greenhouse gas emissions, and microplastics. We sought to estimate whether replacing sterile water with potable tap water for endoscopic irrigation affected clinical outcomes. Methods This quasi-experimental study involved an interrupted time series design at a multi-campus tertiary care academic health system (The Ottawa Hospital, Canada). All adults undergoing esophagogastroduodenoscopy, colonoscopy, flexible sigmoidoscopy, enteroscopy, ileoscopy, or pouchoscopy between February 2024 and August 2025 were included. A system-wide switch to tap water took place on February 10, 2025. The primary outcome was a composite of emergency department visits, unplanned admissions, or deaths within 7 days post-procedure. Infectious complications within 30 days constituted secondary endpoints. Data were obtained from validated institutional databases. Segmented regression modeled the weekly outcome proportion to estimate the step change post-implementation, with a non-inferiority margin of <0.5% absolute risk increase. Findings A total of 29,522 procedures were performed on 29,423 patients (18,863 pre-implementation; 10,560 post-implementation). Patient and procedural characteristics were comparable. The weekly proportion experiencing the primary outcome was 1.6% in both phases. The post-implementation step change was −0.40% (95% confidence interval [CI] −1.16 to 0.35), with the upper boundary of the 95% CI below the pre-specified non-inferiority margin of 0.5%. Results were similar for infectious complications (step change −0.23%, 95% CI −0.75 to 0.29). Interpretation Potable tap water was non-inferior to sterile water for endoscopic irrigation with respect to clinical outcomes. These findings provide an evidence base for revising current guideline recommendations that mandate sterile water for endoscopic irrigation. Funding This project was supported by the 2024 Canadian Society of Colorectal Surgeons Research Operating Grant.

More Papers Like This

Article

Scope sustainability: slashing single-use plastic bottles

AI summary Read the abstract

A quality improvement initiative at a hospital endoscopy program replaced sterile water in single-use plastic bottles with tap water in reusable containers, eliminating the use of 480 bottles in the first two weeks and preventing the release of 115 million microplastics and nanoplastics. Annual cost savings of CAD $47,145 were projected, with no increase in procedural complications observed.

Article Tier 2

Microplastics throughout a tap water supply network

AI summary Read the abstract

Researchers evaluated microplastic presence throughout a large tap water distribution network, detecting microplastics at multiple points from treatment plant to consumer taps and finding that concentrations increased along the distribution system, suggesting the pipe network itself as a contamination source.

Article Tier 2

Impact of Using Commercial Cleaning Facilities on the Safety of Food Contact Surfaces of Reusable Cups

AI summary Read the abstract

Researchers evaluated the safety of food contact surfaces on reusable cups after commercial cleaning, analysing microbiological risks at each cleaning step, residual allergens, and microplastic contamination, and found that disinfection and drying processes reduced microbial loads but microplastic residues remained a concern.

Article Tier 2

Rethinking The Surgical Field: The Impact Of OR Draping Practices On Waste And Carbon Emissions

AI summary Read the abstract

Surgeons found that using fewer disposable gowns and drapes for minor skin surgeries cut medical waste by over 3 kg per procedure, cut costs by thousands of dollars, and didn't increase infection risk. This matters because those disposable materials are made from non-biodegradable plastic that's carbon-intensive to produce, so simple changes to surgical routines could meaningfully shrink hospitals' environmental footprint without compromising patient safety.

Article Tier 2

A Study of Microplastic Particles in Danish Tap Water

AI summary Read the abstract

Researchers investigated microplastic presence in tap water from 17 households and workplaces across Denmark using careful contamination controls. They found a low level of microplastic particles in Danish drinking water, with most particles being small fragments or fibers. The study suggests that while microplastics are detectable in treated tap water, the concentrations found in Denmark's well-maintained water infrastructure were relatively low.

Research digests by email

When a large batch of papers lands in the Atlas, we read through it and send a short write-up of what stood out.

Email me about

Share this paper