0
Article Tier 2 Remediation Sign in to save

Investigating the impact of low-pressure reverse osmosis membrane aging and heterogeneity on performance: A study of virus and microplastic retention

Separation and Purification Technology 2025 1 citation

AI summary Read the abstract

Researchers tested how aging affects the performance of low-pressure reverse osmosis membranes used to produce drinking water, finding that while older membranes became more permeable and less effective at blocking salt, they still completely retained viruses and microplastics. However, physical defects like folds and glue patches — not age itself — allowed viruses to pass through, underscoring the importance of membrane integrity over age in water safety.

Study Type Environmental

The increasing demand for freshwater, alongside increasing microplastics and persistent microbiological contaminants, is degrading water quality and highlighting the need for advanced treatment processes with better retention performance. Low-pressure reverse osmosis (LPRO) presents a promising solution for producing drinking water from freshwater, offering an optimal balance between water quality and production costs. However, uncertainties remain regarding the long-term evolution of these performance metrics, which are primarily based on data from reverse osmosis membranes used in seawater desalination. This study investigates the impact of membrane aging on LPRO performance and the role of membrane heterogeneity within a spiral-wound module. New and long-term aged membranes were compared in terms of permeability, salt retention, and virus retention, with additional analysis of microplastic retention. Natural membrane aging led to increased permeability and decreased salt retention, without affecting virus and microplastic retention, for which retention remained total across the tested coupons. Performance heterogeneity was observed depending on the position of the coupons within the module, with a more significant degradation at the beginning of the module and winding, likely due to mechanical effects associated with higher pressure and deformation. In contrast, coupons located at the end of the module and winding showed minimal performance impact. No impact was observed on virus and microplastic retention, which remained complete, confirming that viruses do not pass through an intact membrane but rather through membrane defects and seals. Autopsy of the LPRO modules revealed membrane defects (glue patches, minor and major folds) that affected membrane performance. In particular, the presence of apparent major folds led to significant performance degradation, with lower permeability and salt retention. The folds also caused the passage of viruses into the permeate, while microplastic retention remained unaffected. The virus passing through the permeate of an LPRO pilot would therefore be due to defects in the membrane and O-rings of the modules.

More Papers Like This

Article Tier 2

Analysis of membrane surface after the filtration of surface water containing microplastic

AI summary Read the abstract

Researchers tested ultrafiltration and nanofiltration membranes on real river water containing microplastics and found both membrane types completely removed plastic particles from the filtered water, though the deposited microplastics reduced water flow through the membranes over time — confirming membrane filtration as an effective but imperfect water treatment strategy.

Article Tier 2

Do membrane filtration systems in drinking water treatment plants release nano/microplastics?

AI summary Read the abstract

Analysis of membrane filtration systems in drinking water treatment plants found that physical cleaning, chemical exposure, aging, and mechanical wear can all cause membranes to release nano/microplastics into the treated water supply — identifying treatment infrastructure itself as a potential source of plastic contamination.

Article Tier 2

Purifying or polluting? Tracing membrane-based microplastics release for long-term drinking water safety

AI summary Read the abstract

This study investigated whether the polymeric membranes used in drinking water filtration systems might themselves release microplastics, and researchers found that chemical cleaning and pre-oxidation treatments significantly increased particle shedding. Most released particles were in the concerning 1-to-5 micrometer size range, though the research also identified operating conditions under which membrane systems remain effective net purifiers over time.

Article Tier 2

Advanced Water Production via Point of Use Super‐Ultralow‐Pressure Reverse Osmosis and Cellulose‐Polyamide Thin‐Film Nanocomposite Membranes

AI summary Read the abstract

This study developed a new type of reverse osmosis membrane for home water purification that works at unusually low pressure, making it more energy-efficient than conventional systems. The membrane incorporates cellulose nanofibers to improve water flow, salt rejection, and resistance to fouling and chlorine. While the study focuses on membrane engineering rather than microplastics specifically, improved point-of-use filtration technology is relevant to reducing microplastic exposure from drinking water.

Article Tier 2

Release of microplastics from polymeric ultrafiltration membrane system for drinking water treatment under different operating conditions

AI summary Read the abstract

Researchers discovered that the plastic membrane filters used to purify drinking water can actually release microplastics into the treated water. The particles came not just from the membrane itself but also from plastic equipment in the system, meaning that water treatment technology designed to remove contaminants may inadvertently be adding new plastic particles to our drinking water.